Mitsubishi Electric Mr.SLIM SLZ-KF25VA2 Manuel D'utilisation page 10

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 34
3. Operation
Manual vane angle (Wired remote controller)
Main
Main menu
Maintenance
Initial setting
Service
Main display:
Cursor
Page
F1
F2
F3
F4
Maintenance menu
Auto descending panel
Manual vane angle
3D i-See sensor
Main menu:
Cursor
F1
F2
F3
F4
Manual vane angle
Ref. address
Unit No.
Identify unit Check button
Input display:
Cur.
Address
Check
F1
F2
F3
F4
Manual vane angle
Select:
Outlet
Angle
F1
F2
F3
F4
Manual vane angle
Setting
Note:
Do not set the draft reduction in an environment with high humidity.
Otherwise, condensation may form and drip.
10
1 Select "Maintenance" from the
Main menu (refer to page 8), and
press the [SELECT] button.
2 Select "Manual vane angle" with
the [F1] or [F2] button, and press
the [SELECT] button.
3 Move the cursor to "Ref. address"
or "Unit No." with the [F1] button to
select.
Select the refrigerant address and
the unit number for the units to
whose vanes are to be fi xed, with
the [F2] or [F3] button, and press
the [SELECT] button.
• Ref. address: Refrigerant address
• Unit No.: 1, 2, 3, 4
Press the [F4] button to confi rm the
unit.
The vane of only the target indoor
unit is pointing downward.
4 The current vane setting will ap-
pear.
Select the desired outlets from 1
through 4 with the [F1] or [F2] but-
ton.
• Outlet: "1", "2", "3", "4" and "1, 2, 3,
4, (all outlets)"
Press the [F3] or [F4] button to go
through the option in the order of
"No setting (reset)," "Step 1", "Step
2", "Step 3", "Step 4", "Step 5" and
"Draft reduction*".
Select the desired setting.
* Draft reduction
The airfl ow direction for this setting
is more horizontal than the airfl ow
direction for the "Step 1" setting in
order to reduce a drafty feeling.
The draft reduction can be set for
only 1 vane.
Vane setting
No setting
Step 1
Step 3
Step 4
Draft
All outlets
reduction*
Press the [SELECT] button to save the settings.
A screen will appear that indicates the setting information is being trans-
mitted.
The setting changes will be made to the selected outlet.
The screen will automatically return to the one shown above (step 5) when
the transmission is completed.
Make the settings for other outlets, following the same procedures.
If all outlets are selected,
the unit goes into operation.
Navigating through the screens
• To go back to the Main menu ................ [MENU] button
• To return to the previous screen .......... [RETURN] button
Manual vane angle (Wireless remote controller)
Fig. 1
Fig. 2
Fig. 3
Display
Setting
Step 1
Display
Setting
Step 5
No setting
* The draft reduction can be set for only 1 vane.
The setting is enabled only for the last vane that was set.
Step 2
Step 5
will be displayed the next time
1 Going to the Manual vane setting
mode
Press the
button.
(Start this operation from the status
of remote controller display turned
off.)
"FUNCTION" is lighted and "1"
blinks. (Fig. 1)
Press the
button to select "2",
and then press the
2 Selecting the vane number (Fig. 2)
Press the
buttons to select the
vane number A, and then press
the
button.
A
3 Setting the vane angle (Fig. 3)
Press the
buttons to select the
vane angle B.
Point the wireless remote controller
B
toward the receiver on the indoor
unit, and then press the
button.
Step 2
Step 3
Step 4
No display
Draft reduction*
button.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mr.slim slz-kf35va2Mr.slim slz-kf50va2Mr.slim slz-kf60va2

Table des Matières