May 1996
Feed:
- Suction cups beyond cover width must be
plugged
up with plastic studs (36).
- The suction cups support bar can be
orientated by loosing screw (37).
- Vacuum is continuously adjustable by
pot (24) for an optimum cover grip.
- Separation air blast is continuously
adjustable by knurled knob (25).
38
40
- The leading edge (41) of the cover store
can be lifted by means of button (42) to
bring very short covers closer to clamping
level.
Make sure to orientate the suction cups
support bar accordingly. (37)
GB/ 10
39
25
-
Cover front separators (38).
Their number, position and stifness is
adjustable for optimum results.
-
Slide separators (38) to the height of
the top hole on the blower bar for best
general result.
-
Unlock screw (39) to move or remove them.
-
Slide blade (40) to change their elasticity.
42
41
37
36