WARRANTY CARD - WARRANTY CONDITIONS
KWAZAR CORPORATION Sp. z o.o provides full warranty and post-warranty service.
1. A sprayer that is sent for repair (regardless of cause) must be complete and clean - free of any spray liquid
residue.
2. Warranty repairs will be performed only if a completed warranty card and proof of purchase is provided
with the sprayer.
3. Warranty and post-warranty repairs are conducted at the seat of the company and in Authorised KWAZAR
Service Centres - the list is available at www.kwazar.com.pl in the SERVICE tab.
SPARE PARTS AND ACCESSORIES
Spare parts are available for the sprayer. For more information, visit www.kwazar.com.pl or the web store
at www.kwazar.com.pl/shop
TROUBLESHOOTING
Always depressurise the tank before performing any maintenance or repair work!!!
SYMPTOMS
Low lance output pressure
(fig. 1/pos. 1).
Irregular stream from the adjustable
nozzle (fig. 10/pos. 1).
Pressure drop in the tank
(fig. 1/pos. 8), spray liquid appears
in the pump cylinder (fig. 1/pos. 5).
No pressure in the tank
(fig. 1/pos. 8) when pumping.
Safety valve (fig. 1/pos. 6)
does not close or open.
Pressure in tank is decreasing
(fig. 1/pos. 8).
No spray liquid stream.
WARRANTY AND SERVICE
CAUSE
Clogged filter (fig. 12/pos. 1)
in the lance handle (fig. 12/pos. 2).
Clogged adjustable nozzle
on the lance tip (fig. 10/pos. 1).
Clogged adjustable nozzle
on the lance tip (fig. 10/pos. 1).
Damaged head seal on the end
of the cylinder pump (fig. 13a/pos. 3).
Damaged seal (fig. 13a/pos. 2)
on the pump piston rod (fig. 1/pos. 5).
Damaged safety valve.
Suction tube fell off the hose.
REMEDY
Remove handle (fig. 12/pos. 2), check filter condition
(fig. 12/pos. 1). Remove any contaminants.
Unscrew the lance tip and remove the adjustable
nozzle (fig. 1 10/pos. 1). It can be disassembled,
cleaned and reassembled.
Unscrew the lance tip and remove the adjustable
nozzle (fig. 10/pos. 1). It can be disassembled,
cleaned and reassembled.
Depressurise the tank with the safety valve (fig. 1/pos. 6).
Remove pump (fig. 1/pos. 5). Check the condition of
the head seal. Replace if damaged.
Depressurise the tank with the safety valve (fig. 1/pos. 6).
Remove pump (fig. 1/pos. 5). Slide the piston rod out
of the cylinder as far as possible. Holding the cylinder,
turn the piston handle counterclockwise, which will
undo the guides and allow you to remove the piston
from the cylinder. Check the condition of the piston
seal (fig. 13a/pos. 2). Replace if damaged. Apply
a small amount of silicone oil (included). Reassemble
by following the procedure backwards.
Lubricate safety valve (fig. 1/pos. 6). With the safety
valve open, apply a few drops of silicone oil inside and
operate it back and forth a little. If the problem persists,
replace the valve.
Depressurise the sprayer with the safety valve
(fig. 1/pos. 6). Remove the hose and properly insert
the suction tube as far as possible applying a turning
motion, then reconnect the hose to the sprayer head.
PL