Dometic TEC 29 EV Notice D'utilisation page 20

Masquer les pouces Voir aussi pour TEC 29 EV:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 58
Operating the generator
Display message
Description
OVER TEMPERATURE
Overheating
LOW POWER ENGINE
The inverter supply voltage has
dropped.
RESTART GEN?
Message appears after the gen-
erator has stopped due to over-
heating.
GEN CAL
Message appears when the gen-
erator is started up; it shows the
calibration phase which takes
place before each start-up. The
generator does not supply any
voltage.
GEN WAIT
Message appears while you are
waiting for the generator to start
again.
GEN ON
The generator is operating nor-
mally.
GEN OFF
AUTO?
Message appears when the
automatic mode is switched on.
AUTO
Automatic mode
20
Generator behaviour
The inverter switches off so no
voltage is supplied to cool the
generator, but the engine car-
ries on running.
The generator stops.
The generator is switched off.
The generator is running but
does not supply any voltage.
The generator is switched off.
Normal mode
The generator is in stand-by and
can be started.
Controls are waiting for user
input
The automatic mode is switched
on
TEC29 EV, TEC29 EV LPG
Measures
Leave the engine to cool down
for a few minutes then start the
generator again.
Reduce the connected load and
start the generator again.
Press the start button to restart
the generator.
Wait a moment.
Wait until the message has disap-
peared then attempt ignition
again.
Press the start button within
20 seconds and hold down for
3 seconds.
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Tec 29 ev lpgTec29Tec29lpg

Table des Matières