G
B
J18
J1
N F
Power supply 230 Vac 50/60 Hz - external to the control
panel - (120 V 60 Hz upon request)
J2
SECONDARY
Connectors for secondary 18 Vac transformer
TRANSFORMER
J3
BATTERY
Connector for 24V battery charger board (code ACG4774
CHARGER (24 V
optional)
DC SOLAR
J4
MOTOR
Connector for 24 Vdc motor and 5 Vdc encoder
J5
Connector for flasher 24Vdc (cod. ACG7061)
Pay attention to the polarity.
J6
A+ COM
+ 24Vdc accessories power supply
A-
- 24Vdc accessories power supply
A+TEST
+ 24Vdc photocells self-test power supply
J7
R-AUX
Auxiliary relay contact (NO) Max 700 W
SIGNAL
Barrier opened warning light, operating signal with battery and
low battery (24Vdc 3W max)
COM A+
Contacts common / Positive 24 Vdc
J8
PHOTO 1
Photocells contact 1 (NC)
PHOTO 2
Photocells contact 2 (NC)
STOP
STOP impulse contact (NC)
TLC
Magnetic sensor contact for traffic light control in PARK mode
COM A+
Common contacts / Positive 24 Vdc
J9
SECURITY LOCK
Connector for manual release switch
(factory connected - DO NOT REMOVE!)
J10
OPEN 1
Opening impulse contact (NO) - to enter
OPEN 2
Opening impulse contact (NO) - to exit
CLOSE
Closing impulse contact (NO)
START
Single pulse contact (NO)
B.I.O.
Contact (NO) dedicated to a timer
OK CLOSE
Contact for closing confirmation in PARK mode
COM A+
Common contacts / Positive 24 Vdc
J1
J2
F1
J3
J17
J16
J15
F
N
J4
J5
J6
J11
J12
APP+
J13
APP
J14
SERIAL COM /
SYNC
J15
RADIO
J16
RADIO
J17
J18
AUX CARD
RUN
TCA
LOW SP.OP.
LOW SP.CL.
PROG
F1
T 2 A
F2
F10 A
24
J7
J8
J14
J12
J13
RS485 termination of J12
Connector for APP+ card
Connector for APP card
Connector for serial connection
Connector for radio receiver RIB, 24 Vdc supply
Connector for radio module ACG8069
433 MHz Radio antenna
Card 1 relay connector (code ACQ9080) for management of
courtesy light.
Card 3 relay connector (code ACQ9081) for management of
courtesy light or traffic lights.
Trimmer for high speed adjustment operations
Trimmer for automatic closing time adjustment (DISABLED
DEFAULT AND DL9 LED OFF)
Electronic regulator for low speed on approach in opening
Electronic regulator for low speed on approach in closure
Programming button
Transformer protection fuse (external to the card P1 24V)
Fuse for motor protection
J9
J10
J11