Télécharger Imprimer la page

GYS EXATIG HF Mode D'emploi page 20

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
MADE IN FRANCE
Setting
Comments
Pregaz
Trigger setting with 4T mode or adjustable
ISTART
% of I1
TSTART
Duration of TSTART
UpSlope
Upslope by second
Welding current setting The setting can be done using
the coder at the font of the EXAGON or using torch
scrollwheel
I1
Ipotar=50%IIHM to 100%IIHM
(ex : if I1=100A => 50A to 100A wheel capacity.)
Display of welding current in A.
PLS
Pulse Mode. From OFF to ON there are 2 menu
Pulse frequency to switch from crt l1 to crt l2 only if PLS
Frq
mode is ON
50% duty cycle
Cld
Cold current
DownSlope DownSlope is adjusted with wheel.
ISTOP
% of I1
TSTOP
Duration of TSTOP
Post-gas
Trigger setting with 4T mode or customizable :
ACCESS TO MENU
Welding MMI
output
20
EXATIG HF
+
x 3s
+
Release of buttons
Current process
settings menu
Exit settings menu
Display
Range of settings Default value
PrE.
0 to 25 sec.
I.St.
10 to 200 %
t.St.
0 to 10 sec.
UP.S.
0 to 25 sec.
xxx
10 to 400 A
"PLS ON
/
PLS OFF"
FrE.
0.1 to 200 Hz
Cld
20 à 80 %
wheel
0 to 25 sec.
I.SO.
10 to 100 %
t.SO.
0 to 10 sec.
Po.G.
0 to 25 sec.
...
...
Only for MMA
and Vertical up MMA
EN
0 sec.
50%
0 sec.
0 sec.
OFF
100 Hz
1 sec.
20%
0 sec.
8 sec.
Load settings
and menu exit
Save settings
and menu exit

Publicité

loading

Ce manuel est également adapté pour:

013780