SEAS ONAL MAINTE NANCE
Consists in:
• Clean the stove internally and externally
• Carefully clean the heat exchange tubes
• Carefully clean and remove dirt from the combustion chamber and the relative compartment
• Clean fans, verify mechanical and clamp loosening
• Clean smoke channel (replace seals on smoke exhaust pipe)
• Clean smoke duct
• Check the expansion tank
• Check and clean the circulator
• Clean smoke extraction fan compartment.
• Clean smoke fl ow sensor.
• Clean smoke check thermocouple.
• Empty the pellet hopper and clean the base with the vacuum cleaner.
• Clean, inspect and scrape any residue from the ignition resistance compartment and if necessary, replace it
• Clean/check the Synoptic Panel
• Visually inspect the electrical wires, connections and power cable
• Clean the pellet hopper and check loosening of the feed screw - gear motor assembly
• Replace the door seal
• Functionality test: load the feed screw, ignite, let it run for 10 minutes and shutdown
If the boiler-stove is used very often, it is recommended to clean the smoke channel every 3 months.
After implementing a normal cleaning procedure, INCORRE CT coupling of the upper (A) (fi gura E) and lower (B) (fi gu-
ra E) combustion chambers can compromise the boiler-stove's performance.
Before igniting the boiler-stove, make sure the combustion chambers are correctly paired as indicated in (fi g. F) without
ash or unburnt material present on the support perimeter.
We remind you that using the stove without cleaning the melting pot, may cause a sudden ignition gas inside the combu-
stion chamber with the consequent breaking of the glass
A
fi g. E
Cleaning the smoke duct
• When the thermo stove is off and cold, agitate the cleaning rod energetically (see previous page).
Remove the lower front cast iron panel (3 - fi g. C) and remove the steel inspection panel (4 - fi g. C/D), complete with silicone
gasket (5 -fi g. D), fi xed with wing nuts. Clean the silicone gasket and vacuum resid from the fl ue pipe (6 - fi g. D).
The thermo stove comes with a spare silicone gasket.
The amount of residue will depend on the type of fuel and system.
Failure to carry out this cleaning procedure may cause the boiler-stove to block.
ONCE THE PROCEDURE IS IMPLEMENTED, ENSURE THATTHE INSPECTION HATCH IS CLOSED PROPERLY.
fi g. C
3
MAINTENANCE
(implemented by the DEALER )
ATTENTION !!!
B
4
fi g. F
fi g. D
5
4
- 53
-