Installation Instructions
■
4-Wire Branch Circuit
Refer to Figure 2:
•
Disconnect ground from neutral at free
end of conduit.
•
Connect the green GROUND wire from
the oven to the GROUND wire in the
junction box (bare or green colored wire).
•
Connect the red and black leads from the
oven to the corresponding HOT Wires in
the junction box.
•
Connect the white wire from the oven to
the NEUTRAL (gray or white) wire in the
junction box.
•
Connect the local codes and power
supply codes using a terminal.
•
The terminal uses a thing adapting to the
wire of the cord.
Important: Use twist-on connector
with square-wire spring
Square-wire spring
EN-24
All manuals and user guides at all-guides.com
Junction box
Red wires
From power supply
Or
From the oven
Ungrounded Neutral
Cable from
power supply
Bare or
green wire
Cable
from oven
Figure 2
Terminal Block
For Installer
White wires
Black wires
U.L.-listed conduit
connector