Heartland 9200 Instructions D'installation Et D'utilisation page 16

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Model 9200
Appliances
How to Steps
Appliance Clearances (see Page 15 for additional details):
Sides of stove to adjacent surfaces: 1/2" (1.5 cm) min
Nickel trim to adjacent surfaces: 0" right and left
Rear clearance: 0"
Closet right side to cabinet: 0"
Top of counter to underside adjacent cabinet: 18" (46
cm)
Cooktop to underside overhead cabinets: 30-1/4" (77
cm)
Edge of range to combustible wall on either side: 6"
(15 cm)
Cut out width for range's main body: 30" (76 cm)
Max. countertop depth: 24" (61 cm); height: 36" (91
cm)
Max. overhead cabinet depth: 13" (33 cm)
Note: If unit is installed beside a refrigerator it is important
that there be at least 5" (13 cm) between the refrigerator
and range for proper air circulation.
Gas
Natural Gas/Propane Conversion kits available from
dealer or factory and must be performed by a licensed
Pressure requirements: Nat Gas: 5" W.C. (min);
LP gas: 11" W.C. (min)
Connection: 1/2" NPT
An accessible manual shut off valve must be installed
at the appliance.
Stove must be installed in compliance with local codes.
In the absence of local codes, with the National Electrical
code ANSI Z223.1 in the US or in Canada with the CSA
Standard B149.1.
Appliances installed in the state of Massachusetts:
This appliance can only be installed in the state of
Massachusetts by a Massachusetts licensed plumber
This appliance must be installed with a three (3) foot /
A "T" handle type manual gas valve must be installed
in the gas supply line to this appliance in an accessible
location.
Electrical
Electrical hookup must be performed by a licensed
electrician.
120 Volts 60Hz .375 Kw.
5 ft (1.5 m) power cord included with 3 prong plug.
Stove must be electrically grounded in compliance with
local codes. In the absence of local codes, with the
National Electrical code ANSI/NFPA 70 "Latest Edition"
in the US or in Canada with the Canadian Electrical
Code, Part I, CSA Standard C22, or the Local National
Electrical Code.
Venting
How to Steps
Option 1 - Ventless installation:
Requires no further set up
(cooking fumes are drawn
and exhausted through
rear of hood, back into the
room.)
Option 2 - Venting directly outside:
Method 1 - Installation
through outside wall.
Method 2 - Installation
through attic to outside.
3 1/4" x 10" Exhaust adaptor included with range
Method 1
Safety
• Maximum ducting run: 25 linear feet - subtract 5' per 90 deg
elbow and 2.5' per 45 deg elbow. Do not use more than two
elbows. All duct work must be metal. Do not use plastic duct.
The range hood should never be exhausted into a wall cavity or
hazard.
• Installation must be completed in accordance with all local &
national codes.
above range should be avoided. Existing min clearance 30-1/4"
(76 cm).
• Use only materials which conform to local codes in e ect.
• Gas cooking appliances produce heat and moisture - ensure
kitchen is well ventilated. Prolonged intensive use may require
additional ventilation (opening windows or addition of supple-
mentary air exhaust sources).
13
.
Method 2

Publicité

Chapitres

Table des Matières
loading

Produits Connexes pour Heartland 9200

Ce manuel est également adapté pour:

7200

Table des Matières