Longer length temperature selector LH (fig. K)
The maximum temperature limiter is engaged. To disengage it:
• Shut-off the water supply.
• Uncsrew the locking screw at the back of the mixer body using a 4mm Allen key
to remove the temperature selector.
• Lift (e.g. using a flat head screwdriver) to remove the limiter o.
• Place the limiter o in position p to achieve full hot water.
Temperature selection via the control lever L 100mm
The product is delivered with the maximum temperature limiter engaged.
To adjust the pre-set, unclip and reposition the index ring located underneath the control lever:
• To access the index ring (fig. L): remove the control lever by unscrewing the grub screw q using a 2.5mm
Allen key.
• To change the hot water (HW) setting (fig. M), unclip black temperature limiter index ring r
and turn clockwise to reduce the hot water temperature setting, or turn anti-clockwise to increase
the temperature. Replace the black index ring r
Beware of the control lever position: the axis of the lever must always be aligned with the axis of the
moving index ring s. Once the lever is in position, check that the maximum temperature is correct.
• To return to the maximum hot water position: align the marker on the black index ring r
with the marker on the red index ring t.
Beware of the control lever position: the axis of the lever must always be aligned with the axis of the
moving index ring s.
Re-assemble and commission in line with the TMV manufacturer's instructions.
INSTALLING THE SPOUT (for mixers/taps with removable spouts)
• Remove the white plastic cap.
• Place the spout on the mixer/tap and screw into place.
MAINTENANCE
• In sleep mode, the YELLOW LED l (fig. F) will be lit. If it goes out, check the voltage at terminal e (fig. E)
and replace the fuse if necessary.
• If the problem persists, replace the electronic unit ref 495445BC.
IF THE MIxER/TAP FLOWS CONTINUOUSLY:
• Shut-off the 230V electricity supply. If the water stops flowing, replace the electronic unit, if not, check
the mounting direction of the solenoid valve, then clean/rinse the outlet, lifting the valve with a small
screwdriver. Replace and do not forget to replace the filter.
IF THE WATER DOES NOT FLOW WHEN HANDS ARE PLACED IN FRONT OF THE DETECTOR:
• RED LED k (fig. F) is lit: the device is in security mode. An object in front of the detection cell has
triggered the anti-blocking safety after the comfort shut-off delay. Remove the object.
• GREEN LED m (fig. F) has gone out: the detection cell is dirty or has a bad connection on the BMR terminal.
- Check and clean the detection cell.
- Check the direction and the quality of the cables.
- Check that the wires are not touching.
- Check that the detector cable has not been lengthened or shortened.
• GREEN LED m (fig. F) is lit and the water is not flowing: the solenoid valve is not opening.
- Check that the filter is clean.
- Check that the power supply to the solenoid valve is 12Vac. If it is, replace the solenoid valve, if not,
check that the supply cable is properly connected to the terminal, or that it has not be cut.
• Mixer: regularly check (as often as necessary) the temperature selector and the mixer's
two internal seats on which the mixing key turns. Replace as necessary.
• The non-return valves should be checked at least once a year.
EN