MAINTENANCE AND USE MANUAL
Fig. 14: It is possible to interrupt mixing at any moment,
even before the end of the programme cycle. Press THE
STOP key (4) for about 2 seconds to interrupt the cycle;
press the same key again to release the vacuum and
detach the cup.
It is necessary to support the cup by
hand at the moment in which the mixing
cycle is interrupted.
Fig. 15: During mixing, in case of unexpected black-out,
rotation will stop and container will be kept
connected. To preserve good quality of material, take off
container just opening draining tap.
Residual risk is:
• a danger that cannot be completely eliminated through design and application of safety devices.
• a potential danger which cannot be highlighted.
To prevent accidents always observe the instructions in this manual. Should you have
any doubts at all please contact the Manufacturer or your Authorised Servicing
Centre.
The above-mentioned dangers are indicated by special labels attached to the machine, as described
in sub-section 3.3.1.