Télécharger Imprimer la page

Berner BCLL BASIC Notice D'utilisation page 64

Laser à réticule
Masquer les pouces Voir aussi pour BCLL BASIC:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 71
MOUNTING ON A GRADE ROD (FIG. F, G)
1. To secure your detector to a grade rod, first attach the detector to the
clamp by pushing in on the clamp latch (26). Slide the tracks (27) on
the clamp around the rail (28) on the detector until the latch (29) on the
clamp pops into the latch hole (30) on the detector.
2. Open the jaws of the clamp by turning the clamp knob (31)
counterclockwise.
3. Position the detector at the height needed and turn the clamp knob
clockwise to secure the clamp on the rod.
4. To make adjustments in height, slightly loosen the clamp, reposition
and retighten.
Detector Cleaning and Storage
• Dirt and grease may be removed from the exterior of the detector
using a cloth or soft, non-metallic brush.
• The Berner digital laser detector is rain resistant but not immersible. Do
not pour water on the unit or submerge it under water.
• The best storage place is one that is cool and dry—away from direct
sunlight and excess heat or cold.
Detector Service
Except for batteries, there are no user serviceable parts in the Digital Laser
Detector. Do not disassemble the unit. Unauth orized tampering with the
laser detector will void all warranties.
Detector Troubleshooting
THE DETECTOR WILL NOT TURN ON.
• Press and release the power button.
• Check to see that the battery is in place and in the proper position.
• If the detector is very cold, allow it to warm up in a heated area.
• Replace the 9-volt battery. Turn the unit on.
E N G L I S H
61

Publicité

loading

Ce manuel est également adapté pour:

Bcll basicline183845