12
Installation
Mount the Unit
Set downdraft into opening and position with the back
of the unit contacting the back edge of the cutout.
Stabilizing brackets should be installed at the bottom
of the vent housing and just below the bottom of the
cooktop chassis.
Lower stabilizing brackets Down and Right
Blower Discharge:
One stabilizing bracket should be installed on each
side of the vent housing.
Remove the hex head screw from the bottom of the
vent housing and use it to attach each bracket to the
bottom of the housing. Slide the brackets to the back
wall of the cabinet so that the vent housing is vertical,
check the level of the vent on both the right and left
sides, and tighten the screws.
Lower stabilizing brackets Left Blower
Discharge:
One stabilizing bracket should be installed on the right
side of the vent housing and one on the left side of
the control box.
Remove the hex head screws from the bottom of the
vent housing and use it to attach each bracket to the
bottom of the housing. Slide the brackets to the back
wall of the cabinet so that the vent housing is vertical,
check the level of the vent on both the right and left
sides, and tighten the screws.
Attach the stabilizing brackets to the back wall using
the appropriate screws for your cabinet material
and thickness. These screws are not supplied with
downdraft system.
The end of the stabilizing bracket may have to be
bent down for transition duct clearance.
Upper stabilizing brackets:
Caution: Do not attach the upper bracket to the
vent with screws, doing so may jam the vent.
Attach a stabilizing bracket to the left and right cabinet
walls just below the bottom of the cooktop chassis.
The long leg of the bracket must be in contact with
the vent housing.
DO NOT
Screw Top
Stabilizing
Brackets to
Chassis
Housing
Remove screws from
the chassis housing
and re-use to install the
brackets.
Verifying Proper Operation
After making the required electrical connections,
confirm proper operation of the blower.
1. Turn on the power supply at the circuit breaker.
2. Refer to the Telescopic Downdraft System
Installation Instructions for further instructions
on verifying the proper operation.
Alternate bracket location:
Remove the screw from the
left side of the control box
and re-use to install the left
bracket. Required for left
side blower discharge.