Electrolux 600cfm Instructions D'utilisation page 4

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4
Important Safety Instructions
TO REDUCE THE RISK OF INJURY TO
PERSONS IN THE EVENT OF A RANGE TOP
GREASE FIRE, OBSERVE THE FOLLOWING*:
• SMOTHER FLAMES with a close-fitting lid,
cookie sheet, or metal tray, then turn off
the burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out
immediately, EVACUATE AND CALL THE FIRE
DEPARTMENT.
• NEVER PICK UP A FLAMING PAN - You may
be burned.
• DO NOT USE WATER, including wet dishcloths
or towels - a violent steam explosion will result.
• Use an extinguisher ONLY if:
A. You know you have a Class ABC
extinguisher, and you already know how to
operate it.
B. The fire is small and contained in the area
where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an
exit.
* Based on "Kitchen Firesafety Tips" published by
NFPA.
SAVE THESE INSTRUCTIONS FOR
FUTURE REFERENCES
• For general ventilating use only. Do not use to
exhaust hazardous or explosive materials and
vapors.
• To reduce risk of fire and to properly exhaust
air, be sure to duct air outside. Do not vent
exhaust air into spaces within walls or ceilings
or into attics, crawl spaces or garages.
• This blower assembly is approved for use with
the following Electrolux Telescoping Downdraft
Systems: EI30DD10KSA, EI36DD10KSA,
FH30DD50MSA and FH36DD50MSA only.
. Use of this blower assembly with any other
product or in any other configuration is
hazardous and voids the product warranty.
NOTE
• Consult a licensed ventilation contractor or
qualified technician for proper installation of
exhaust ducting.
• Locate the cooking area for minimum cross
drafts - away from doors and windows, when
possible.
• Ducts must be of adequate size and duct runs
should be as short and straight as possible.
Where turns are necessary, keep turning radius
as large and smooth as possible.
• The ducting must be air tight. Use a minimum
of 2 sheet metal screws at every duct joint.
Then, seal the duct joints with a high quality
duct tape.
• In duct runs less than 10 equivalent straight
feet, the remote blower may interfere with the
cooktop burner performance due to the high
volume of air moved. An adjustable damper
(not included) should be installed in the
ducting system. The damper can be adjusted
so that proper ventilation and cooktop burner
performance is achieved.
• Installation of duct work should be carefully
planned if it is to go under a concrete slab floor.
The duct trench should be boxed to prevent
collapse from the wet cement. Be sure to allow
room to run the electrical wiring and conduit.

Publicité

Chapitres

Table des Matières
loading