EN
26
Open window function
• If you press the button once, the screen will display the
• If you press the button again, the icon will disappear from the screen.
• When this button is pressed, the unit will beep once.
After the open window function is activated, the device first checks whether the heating
elements are currently active. If the heating elements are active, the program will save
the current room temperature values and measure the room temperature again every 12
minutes.
• If a temperature drop of more than 4 ° C is detected within 30 minutes, the program
will automatically deactivate the heating elements as the device suspects an open
window.
• After the heating has been stopped for 70 minutes, the program will start again to
check whether the window has been closed.
• The unit now will now heat to 1900W for 6 minutes every 30 minutes. If the
temperature rises more than 2 ° C during this period, the window will be assumed
to be closed.
icon