VENTILATION
Local codes prevail. These are the "authority having jurisdiction" as stated by the National
Fire Protection Association, Inc. in NFPA 96-Latest Edition. For further ventilation information
see below.
A ventilation hood may be required to remove heat and cooking odors. The hood and HVAC
installation must meet local codes to gain approval by the authority having jurisdiction.
Requirements may vary throughout the country depending on the location by city, county, and
state. Obtain information from the authority having jurisdiction to determine the requirements
for your installation. Obtain information and review copies of codes or documents that will
be used to inspect and approve your installation. Your ventilation hood supplier and HVAC
contractor should be contacted to provide guidance.
CAUTION
Prevent airflow through the cooking tunnel. Air must NOT be directed onto the oven's
front or rear or to the sides of the cooking area. This can cause incomplete or uneven
baking and increased energy consumption.
ELECTRICAL CONNECTION
Before making any electrical connections to this unit, check that the power supply is adequate
for the voltage, amperage, and phase requirements stated on the rating plate. A wiring diagram
is included herewith.
When installed, this appliance must be electrically grounded and its installation must comply with
the National Electric Code, A NSI-NFPA 70, latest version, manufacturer's installation instructions,
and applicable local municipal building codes. In Canada, all electrical connections are to be
in accordance with CSA C22.1 - Canadian Electrical Code Part 1 and/or local codes.
This appliance is equipped with a five-pole terminal and cord bushing to which the
customer/installer can attach. Each line (L1, L2, L3) should have 230V potential referenced
to the neutral (N) connection. An earth (ground) connection is also provided for a five-
wire system.