Technical data

Suction capacity:
Max. vacuum:
Nominal voltage:
Nominal current: ✱
Frequency:
Power input:
Nominal speed:
Motor features:
Weight:
:
Dimensions
Water separator capacity:
Noise:
Ear protection must be worn!
✱ The tool is offered in different versions for various mains voltages. Please refer to the information on the
type plate for the nominal voltage and nominal current input of your tool.

Safety

Before using this vacuum pump
Carefully read these operating instructions, the list of
safety precautions and the operating instructions for Hil-
ti diamond drilling rigs and accessories.
If holes are to be drilled in a wall
Always use a rope, chain or similar means to additio-
nally secure the drilling rig baseplate.
If holes are to be drilled in a ceiling
Always use anchors and/or the telescopic rail to secu-
re the baseplate.
Please also refer to the operating instructions
for the drilling machine.
Using the vacuum pump
This vacuum pump is designed for use with Hilti dia-
mond drilling systems equipped with a suitable vacu-
um baseplate (please refer to the table). The maximum
permitted drilling diameter is 250 mm.
Use of the vacuum pump is permitted only for fastening
vacuum baseplates. It must not, under any circum-
stances, be used for:
– sucking in substances other than air (e.g. gases)
– removing liquids
.
Printed: 07.07.2013 | Doc-Nr: PUB / 5069649 / 000 / 00
7 m
3
/h
80%
110 V, 120 V, 230 V, 240 V
5.3 A, 4.9 A, 2.5 A, 2.5 A
50/60 Hz
Max. 650 W
2800 r.p.m.
Protection class I (earthed/grounded)
Protection type IP54
Thermal overload protection
12.4 kg
×
365×230×268
(length
width
approx. 3.5 litres
Typical A-weighted noise levels of the machine are:
Noise (pressure) level 78 dB (A)
Noise (power) level 91 dB (A)
Drilling system / baseplate combinations
Drilling motor
Baseplate
DD100, DD-80E: DD-100-RA, DD-80-RA,
with DD-VH1
DD-80-RAL/H
DD-BA-4
DD-BV-P *
DD160-E:
DD-BA-4
DD-BV-P *
DD250-E:
DD-BA-10
DD-BV-P *
DCM1, DCM1,5: Standard vacuum baseplate
DCM2:
DCM vacuum baseplate, small
DCM vacuum baseplate, large
DCM vacuum baseplate for pipe
*
The DD-BV-P baseplate may be used only for drilling on curved surfaces
(e.g. drainage pipes)
Diameter range
For concrete pipes of diameter 25 to 80 cm:
DD-BV-P 25/80 baseplate
For concrete pipes of diameter 50 to 200 cm:
DD-BV-P 50/200 baseplate
(specific to country)
(specific to country)
×