3
Wall applications
Mount the device on the wall for horizontal and vertical
levelling. Then align the device with the vials.
4
Mounting on the wall
1. Place device on the wall.
2. Push the special pins through
the appropriate holes.
Technical Data
Angle accuracy
Operating range
(depending on room illumination)
Laser wavelength
Laser class /
line laser output power
Power supply / Operating time
Operating temperature
Storage temperature
Dimensions (W x H x D)
Weight (incl. batteries)
Subject to technical changes 01.2015
!
Regularly check the calibration before use, after
transport and after extended periods of storage.
5
Checking the vertical line
Fix a plumb bob with a line at least 2,5 m in length on the
wall, making sure that the bob can swing freely. Switch on the
laser, direct the lines at the plumb and align the bubble levels (2).
The precision is within tolerance if the deviation between the
laser line and plumb line is not greater than 0,5 mm / 1 m.
08
GB
± 0,5 mm / 1 m
15 m
635 nm
2 / < 1 mW
2 x 1,5V AA / 15 h
0°C...+ 50°C
-10°C...+ 70°C
200 x 48 x 100 mm
240 g