24
Valeurs de sécurité intrinsèque
Mode de protection Ex ia
Variante de commande "Sortie"
Option A
Option B
Option C
Option D
Option E
Option G
Type de sortie
4-20mA HART
4-20mA HART
Sortie impulsion/fréquence/tor
4-20mA HART
4-20mA analogique
4-20mA HART
Sortie impulsion/fréquence/tor
Entrée courant 4...20 mA
FOUNDATION Fieldbus
Sortie impulsion/fréquence/tor
PROFIBUS PA
Sortie impulsion/fréquence/tor
Proline Prowirl F 200
Valeurs de sécurité intrinsèque
U
= DC 30 V
i
I
= 300 mA
i
P
= 1 W
i
L
= 0 μH
i
C
= 5 nF
i
U
= DC 30 V
i
I
= 300 mA
i
P
= 1 W
i
L
= 0 μH
i
C
= 5 nF
i
U
= DC 30 V
i
I
= 300 mA
i
P
= 1 W
i
L
= 0 μH
i
C
= 6 nF
i
U
= DC 30 V
i
I
= 300 mA
i
P
= 1 W
i
L
= 0 μH
i
C
= 30 nF
i
U
= DC 30 V
i
I
= 300 mA
i
P
= 1 W
i
L
= 0 μH
i
C
= 5 nF
i
U
= DC 30 V
i
I
= 300 mA
i
P
= 1 W
i
L
= 0 μH
i
C
= 6 nF
i
U
= DC 30 V
i
I
= 300 mA
i
P
= 1 W
i
L
= 0 μH
i
C
= 5 nF
i
STANDARD
FISCO
U
= 30 V
U
= 17,5 V
i
i
L
= 300 mA
L
= 550 mA
i
i
P
= 1,2 W
P
= 5,5 W
i
i
L
= 10 µH
L
= 10 µH
i
i
C
= 5 nF
C
= 5 nF
i
i
U
= 30 V
i
L
= 300 mA
i
P
= 1 W
i
L
= 0 µH
i
C
= 6 nF
i
STANDARD
FISCO
U
= 30 V
U
= 17,5 V
i
i
L
= 300 mA
L
= 550 mA
i
i
P
= 1,2 W
P
= 5,5 W
i
i
L
= 10 µH
L
= 10 µH
i
i
C
= 5 nF
C
= 5 nF
i
i
U
= 30 V
i
L
= 300 mA
i
P
= 1 W
i
L
= 0 µH
i
C
= 6 nF
i
Endress+Hauser