Test result of an unshielded 4-pair data cable, standard T-568-B
wiring, Remote Unit attached, tested with 1-2, 3 -6 split; screen
plays as:
1. When test is in progress "Test" blinks;
when test is completed, error
(Split 12, 36) was found, "Test" goes off
and is replaced by "Fail". The third row
displays split pin numbers 1236 and
blinks.
2. Error message "Split 1236" shown on last line replacing cable length.
3. Minimum cable length for testing = 1.0 meter or 3 ft.
Test result of an unshielded 4-pair data cable, standard T-568-B
wiring, Remote #1 in use; tested with 1-2 Opened, 3-6 shorted,
7-8 mis-wired; screen displays multiple errors as:
1. When test is in progress "Test" blinks;
when test is completed and multiple
errors detected, "Test" goes off and is
replaced by "Fail".
2. On the third row, screen displays pin
numbers*45*87 where errors such as
Open1-2, Short 3-6, 7-8 mis-wired were
detected.
3. Multiple errors messages are displayed
on the last row cycling in orders of
severity with Short comes first.
COAX (RJ-45) - Coax Cable Test
1. When in Coax (RJ45) mode, press
SELECT to perform test;
2. The Coax (RJ45) mode is used in
conjunction with eight special numbered
and color-coded F-Connectors Terminals,
each has its signature that the IE Net Pro can identify.
3. When using Coax (RJ45) mode, the Split Pair function is automatically
disabled.
Fail
RJ45
12345678
12345678
Split 1236
Fail
RJ45
12345678
Short 36
Cycling in sequential order of
Short
36
Open
1-2
Miswire 78
MODE=ESC, SEL=go
8
No Shield
ID 1
No Shield
4 5*87
ID 1
COAX (RJ45)