Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

This manual has been prepared to enable a correct installation, regulation and maintenance of the appliance; it is therefore of fundamental importance that:
v
The warnings contained in this booklet are read carefully as they supply
essential indications regarding the safety of the installation, use and
maintenance.
v
This manual and the wiring diagram must be stored with care and made
available to the operator for any future consultation.
v
The appliance must be installed, tested and serviced by qualified personnel in
possession of the legal qualifications.
v
The constructor declines all responsibility with invalidity of the warranty in the
event of electrical and/or mechanical modifications. Any adjustment
whatsoever not expressly authorised and in disrespect of this manual
invalidate the warranty.
v
Observe all existing local regulations at the time of installation.
v
Verify that the mains line characteristics are conform to the data given on the
serial plate of the appliance.
GENERAL TECHNICAL DATA
MODEL
DIMENSIONS AND CAPACITY
External dimensions
Length
Width
Height
Total capacity
GENERAL TECHNICAL DATA
Standard voltage
Version
Cooling system
Compr temperatures
Worjing temperatures
Absorbed current
Absorbed power
Type defrost
Defrost ne / max duration min
Type refrigerant
WEIGHTS AND VOLUMES
Gross weights
Packaged volume
¬
Under CECOMAF conditions -10 evaporation +55 condensation.
By remote appliances with cooling unit placed at a distance until 10 m, we suggest to increase of a 20% rating the compressor capacity.
For other data, please check the tecnical label on the appliance.

GENERAL NOTICES

1P
1PV
1PP 1PPM 1PPV
A (mm)
B (mm)
1053
C (mm)
Lt
1200
V
Capillary
W
302 ¬
°C
A
2.3
3.1
W
520
570
Kg
270
mc
v
The packing materials (plastic bags, polystyrene, nails, etc.) as potential
hazards, must be kept out of the reach of children and properly recycled of
according to existing local regulations.
v
The appliance has been designed and constructed for the conservation of
foodstuffs and should therefore be destined to this sole purpose for which it
has been expressly conceived. Any use whatsoever other this specific
purpose does not commit the constructor in any way whatsoever.
v
Shutdown the appliance in the event of breakdown or malfunctions.
v
For eventual repairs contact exclusively the service centres authorised by the
constructor and request the use of original spare parts.
v
If in doubt do not use the appliance and contact professionally qualified
personnel.
v
The disrespect of the above conditions could risk the safety of the appliance.
ROLL-IN TN
2P
880
1046
2250
230/1/50
Ventilated
+2 / +10
2.3
2.4
2.6
5.8
520
560
600
1327
Pause
R134a
290
2.3
­ Under
CECOMAF conditions-30 evaporation +55 condensation.
13
2PV
2PP 2PPM 2PPV
1760
1053
1046
2400
With valve
994 ¬
6.2
5.8
6.2
1427
1327
1427
4 / 30
470
500
4.5
ROLL-IN BT
1P
1PP
880
1053
1046
2290
1200
522 ­
-15 / -20
6.5
5.2
1487
1198
Elettrical
R404A
270
290
2.3

Publicité

Table des Matières
loading