3B SCIENTIFIC® PHYSICS
3B SCIENTIFIC
3B SCIENTIFIC
3B SCIENTIFIC
3B SCIENTIFIC
U10010 Ultrasonic Echoscope and Accessories
Operating instructions
6/04 ALF
1
2
34 5
bu
bt
bs
br
bq
bp
bo
Safety instructions
For your own safety and that of the equipment, please
read the following instructions thoroughly before us-
ing this ultrasonic device and its accessories.
The slits in the device are for ventilation and must not
be covered to avoid overheating of the equipment. We
recommended that the feet on the device be used.
Ensure that the specified operating voltage and safety
measures are observed.
Never try to insert objects through the ventilation slits
since this could lead to short circuits or electric shocks.
Connect only the ultrasonic transducer supplied by 3B
Scientific GmbH to the "PROBE" sockets. Caution: the
transmitting transducer may experience voltage pulses
as high as 300 V.
Be aware that this is laboratory equipment and not a
medical appliance. The ultrasonic sensors are not to
be used on people or animals.
All rights are reserved by 3B Scientific GmbH. No part of this operating manual may be reproduced, rewritten, copied
or redistributed in any form without the express permission of 3B Scientific GmbH.
3B Scientific GmbH accepts no responsibility for damage caused by incorrect use of the equipment, nor for any
repairs or modification made by third parties other than those authorized by 3B Scientific GmbH.
PHYSICS
PHYSICS
PHYSICS
PHYSICS
6
bn
bm
bl
9
1
Start point for time-dependent amplification
2
Trigger slope (rise time) for time-dependent amplification
3
Width of time-dependent amplification
4
Threshold for time-dependent amplification
5
Transmitter power
6
Receiver gain
7
Power supply
8
Mains switch
9
Receiver unit
7
bl
Probe connection for reflection mode
or receiver in transmission mode
bm
Reflection/transmission mode changeover switch
8
bn
Probe connection for transmission mode
bo
Transmitter unit
bp
Clocking unit (time-dependent amplifier)
bq
Connector sockets for oscilloscope
br
Signal output A scan (LF signal)
bs
Signal output (HF signal)
bt
Signal output for trigger signal
bu
Signal output for time-dependent amplifier ramp
1.
2.
Components .........................................12
2.1.
U10010 Ultrasonic echoscope controls ....... 12
2.2.
2.2.1. U10015 1-MHz ultrasonic transducer ......... 12
2.2.2. U10017 4-MHz ultrasonic transducer ......... 12
2.3.
Accessories ................................................. 12
2.3.1. U10027 Acrylic block with holes ................. 12
2.3.2. U10020 Equipment set for longitudinal
and transverse waves .................................. 12
2.3.3. U10022 Aluminum block with
protractor scale .......................................... 13
2.3.4. U10023 Polyoxymethylene (POM) plate
2.3.5. U10025 Reflection plate ............................. 13
2.3.6. U10026 Set of three cylinders ..................... 13
2.3.7. U10029 Heart valve model ......................... 13
11
Contents
®