Anleitung_SKA_2503_Dual_C_H_SPK7:_
(Fig. 8).
6. Close the front panel again.
Cleaning the heat exchanger of the indoor device
The heat exchanger must be cleaned at least once
annually. To do this, remove the air filters from the
indoor device as described above.
Using a vacuum cleaner or a long-bristled brush,
carefully remove any dirt deposits on the heat
exchanger; this will avoid damaging the heat
exchanger fins. A damaged heat exchanger will
lead to higher operating costs.
Take steps to ensure that you do not injure
yourself on the fin edges!

10. General notes

Restarting after lengthy non-use
If the air-conditioning system has not been used for a
lengthy period, check the following before you switch
it on:
1. there are no objects covering the outdoor or
indoor unit.
2. the socket from which the unit is operated has
been installed correctly
3. the air filters are clean
Care precautions
If the air conditioner is not going to be used for some
period of time:
1. Let the fans run for 6 hours to allow the device to
completely dry out. Set the highest possible
temperature level while the fans are running.
2. Switch off the device and pull the power plug.
3. Clean the air filters and housing parts.
4. Remove all dirt from the outdoor unit.
5. Take the batteries out of the remote control.
If the following events occur during operation,
they do not constitute a fault.
1. Safety function of the air conditioning system,
compressor trip
a) After the system has been switched on again,
the compressor will not cut in until after a delay
of three minutes.
b) The device has a special function that prevents
cold air being blown out in heat mode if the heat
exchanger in the indoor device is in one of the
following situations and the set temperature has
not yet been reached:
– Heat mode has just been started.
– De-icing taking place.
– Heat mode with a low temperature setting.
c) The internal and external fans will be shut down
30.07.2008
12:16 Uhr
Seite 29
during de-icing. De-icing is taking place.
d) If the outdoor temperature is high and the
humidity is high, the outdoor device may ice up
whilst it is operating. This will result in reduced
heat output by the air conditioning system. If this
is the case the air conditioning system will
terminate heat mode and start de-icing mode
automatically. The de-icing time may be 4 – 10
minutes depending on the outdoor temperature
and the amount of ice deposited on the outdoor
device.
2. "White mist" is emitted from the indoor device
a) If the temperature difference between the air inlet
and air outlet is large and the relative humidity in
the room is also high. "white mist" may be
generated in cool mode.
b) If the air conditioning system is restarted in heat
mode after de-icing, "white mist" may be
generated by moisture in certain circumstances.
3. A low noise is emitted by the air conditioning
system
a) When the compressor is running or shortly after
it has been switched off, a hissing noise may be
heard, caused by the refrigerant flowing through
the pipes.
b) When the compressor is running or shortly after
it has been switched off, a "screeching" noise
may be audible, caused by the heat expansion
and cold contraction of the plastic parts in the
device due to temperature changes.
c) The first time the power supply is switched on,
the air flap will return to its initial position.
4. Dust is blown out of the indoor device
a) This is normal if the air conditioning system has
been switched off for a lengthy period of time
and when it is started for the first time.
5. A strange odor emanates from the indoor
device
a) This odor is generated in the indoor device and
is emitted by certain materials or pieces of
furniture or by cigarette smoke.
6. The air conditioning system switches to
exclusive fan mode from cool or heat mode
When the indoor temperature has reached the set
temperature, the compressor will cut out
automatically and the air conditioning system will be
operated in FAN mode. As soon as the indoor
temperature in COOL mode rises above the set
value or in HEAT mode it falls under the set value,