become very hot. For this reason keep all cables
away from the copper lines.
CAUTION!
Read all safety regulations and instructions.
Any errors made in following the safety regulations
and instructions may result in an electric shock, fire
and/or serious injury.
Keep all safety regulations and instructions in a
safe place for future use.
Packaging:
The unit is supplied in packaging to prevent it from
being damaged in transit. The raw materials in this
packaging can be reused or recycled.
Tips on saving energy
Only use the air conditioner when you really need to.
Do not select too high a temperature for heating or
too low a temperature for cooling. Select the "Sleep"
function during the night.
Close all windows, doors and Venetian blinds in
order to reduce incoming sunlight as far as possible.
Principle of operation for cooling
Heat is extracted from the air in the room by the air
heat-exchanger (evaporator) in which the coolant
circulates. This air is conveyed to the outside air
heat-exchanger (condenser).
This gives off heat to the outdoor air. Electrical
energy is required for this. In certain circumstances
condensation may form on the evaporator on the
indoor unit, which will be removed by the
condensation hose.
Principle of operation for heating
In heating mode, heat is removed from the outdoor
air by the outdoor device and fed into the indoor
device. This passes the heat on to the room which it
is to heat. Electrical energy is required for this. In
certain circumstances condensation may be
produced on the outdoor device, which must be
discharged via the condensation drain on the
underside of the outdoor device.

2. Items supplied

1 indoor device IA (box 1, art. no. 23.654.64)
1 indoor device IB (box 2, art. no. 23.654.65)
1 outdoor device (box 3, art. no. 23.654.66)
24
30.07.2008
12:16 Uhr
Seite 24

3. Technical data

cooling capacity
Heating capacity
Power rating in cooling mode
Power rating in heating mode
Energy efficiency
Air capacity
Absorbed humidity (30°C/80% RH)
Timer
Operating voltage
Socket fusing
Nominal power consumption, cooling (EN 60335)
Nominal current consumption, cooling
Nominal power consumption, heating (EN 60335)
Nominal current consumption, heating
Compressor
Compressor starting current
Outside operating temperature, heating
Outdoor temperature, cooling operation
Fluid line Ø A
Suction pipe Ø A
Length of refrigerant line supplied
Length of refrigerant line, max.
Max. difference in height between indoor/outdoor
device
Refrigerant
Refrigerant filling capacity
Refrigerant refill quantity from 5 m
Sound pressure level
Inside
Outside
Dimension Inside
Dimension Outside
Weight Inside
Weight Outside
Note:
The specified capacities and performances are
based on the following conditions (EN 14511):
Cooling:
Air temperature at the inlet on the indoor device:
27°C for dry thermometer bulb (DB), 19°C for wet
2 x 2850 watts
2 x 2850 watts
2 x 980 watts
2 x 980 watts
C (EER 2.91/COP 2.94)
550 m
3
/h
1.0 l/h
24 h
230 V ~ 50 Hz
16 A
2460 watts
11 A
2460 watts
11 A
Rotary piston
20 A
0° - +24°C
+18° - +43 °C
6.35 mm
9.53 mm
2 x 4 m
2 x 10 m
5 m
R 410 A
2 x 900 g
15 g/m
≤ 40 dB (A)
≤ 57 dB (A)
75 x 31,5 x 26 cm
102 x 70 x 41 cm
8 kg
65 kg