Napoleon Ascent Serie Manuel D'installation page 27

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Minimum Rear Vent Clearances
For rear vent termination not exceeding 10" (254mm) of horizontal vent run.
64"
(163cm)
Ceiling (min.)
Horizontal vent sections: A minimum clearance of 3" (76mm) on the top outside of the enclosure and 1"
(25mm) on the sides and bottom outside of the enclosure all around the vent pipe on all horizontal runs to com-
bustibles is required. Horizontal vent sections within enclosures require a minimum clearance of 3" (76.2mm) at
the top of the vent pipe.
Vertical vent sections: A minimum of 1" (25mm) all around the vent pipe on all vertical runs to combustibles is
required except for clearances in appliances enclosures. Vertical vent sections within enclosures require a mini-
mum clearance of 1" (25mm) around the vent pipe.
REAR EXIT ENCLOSURE
The appliance requires a minimum enclosure height of 47" (119.4cm). For temperature requirements, the enclo-
sure space around and above the appliance must be left unobstructed.
* See "venting requirements" and "venting installation" sections.
note:
Universal Heat Management kit not available for rear vent installations unless used in a TV recess application.
Enclosure top
8"
6" (152mm)
(203mm)
non-
non-
combustible
combustible
material
material
47"
(119.4cm)
42"
(106.7cm)
rough framing
2"
(51mm)
28 1/2"
(72.4cm)
Minimum
plus rise*
W415-2912 / D / 03.25.21
EN
27

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

D42ntreDx42ntreD42ptreDx42ptre

Table des Matières