2.8

top exit

WARNING
!
Failure to create a seal to the fi rebox with the exhaust collar assembly will cause the appliance to function
improperly and can cause injury or property damage.
note:
This appliance has been factory shipped as a top vent.
A.
Remove the safety barrier and glass door (see "safety barrier & door removal / installation" section).
B.
Remove the contents from the log box and set aside. You will need the exhaust, air inlet collars and
gaskets (supplied).
C.
Remove both 1 1/2" (38.1mm) thick batts of insulation and discard (Fig. 1).
D.
Place the 8" (203mm) intake collar and gasket onto the top of the appliance and secure using 4 screws.
tip:
The manual baggie supplies the gasket and screws (packaged in another separate baggie).
8" INTAKE COLLAR
GASKET
2 x INSULATION BATT
#4 X 10
(1 1/2")
venting requirements
#7 X 4
X 2
Fig. 1