HOLD MODE
Hold Mode is used to disable the pumps during service functions like cleaning or replacing the
filter. Hold Mode will last for 1 hour unless the mode is exited manually. If spa service will require
more than an hour, it may be best to simply shut down power to the spa.
UTILITIES
The Utilities Menu contains the following:
A/B Temps
When this is set to On, the A/B temperature will display in the top right corner indicating the
temperature of the sensors mounted in the heater.
Fault Log
The Fault Log is a record of the last 24 faults that can be reviewed by a service tech.
Fault Log
Entry 2
Back
Message Code M026
1 Days Ago
Rest Mode
High Range
Set Temp 104°F
Sensors: A: 100 B: 96
Message:
Sensors are out of sync
GFCI Test
When this feature is activated the control system will simulate a ground fault problem and trip the
main GFCI circuit breaker that provides power to the spa and the system will shut down complete-
ly. You must then reset the main GFCI breaker for the system to begin operating again.
DO NOT DIVE.
2:21PM
56