7.2.2 Data setting operation:
The following parameters can be adjusted:
battery capacity
-
battery temperature compensation
-
battery type
-
Procedure:
Use K2 or K3 to select the display option with data to be adjusted.
-
Press K1 to enter setting mode.
-
Press K2 or K3 to modify data.
-
Press K1 to save the modified setting, or press K4 to return to previous
-
setting.
7.2.3. More about the adjustable parameters
Battery capacity:
Range: from 10Ah to 900Ah, in 10Ah steps.
-
Default value: 200Ah.
-
Battery temperature compensation:
Range: from 0 to 10mV/Cell/° C.
-
Default value: 5mV/Cell/° C.
-
Battery type:
Three battery types can be chosen:
Sealed generic (SEL),
-
Flooded generic (FLD),
-
GEL generic (GEL).
-
The default setting is GEL.
The corresponding charge voltages are given in section 5. Please choose the
charge voltage that is closest the recommendation of the battery manufacturer.
7.2.4. Resetting total charged/discharged values
1.
Use K2 or K3 to select the "total charged" or "total discharged" screen.
2.
Press K1 to enter setting mode.
3.
Press K4 to reset to zero.
14