30" GAS RANGE INSTALLATION INSTRUCTIONS
2

Provide an adequate Gas Supply

When shipped from the factory, this unit is designed
to operate on 4" water column (1,0 kPa) Natural gas
manifold pressure. A convertible pressure regulator
is connected to the range manifold and MUST be
connected in series with the gas supply line. If LP/
Propane conversion kit has been used, follow
instructions provided with the kit for converting the
pressure regulator to LP/Propane use.
Care must be taken during installation of range not to
obstruct the fl ow of combustion and ventilation air.
NOTE:
The electric
outlet can
be placed
anywhere in
the hatched
area.
Recommended hole
NOTE:
location for through the
The gas entry
fl oor gas entry line.
line hole can
be also placed
anywhere in
the hatched
area.
For proper operation, the maximum inlet pressure to
the regulator should be no more than 14" of water
column pressure (3,5 kPa). The inlet pressure to the
regulator must be at least 1" (0,25 kPa) greater than
the regulator manifold pressure setting. Examples:
If regulator is set for natural gas 4" (1 kPa) manifold
pressure, inlet pressure must be at least 5" (1,2 kPa); if
regulator has been converted for LP/Propane gas 10"
(2,5 kPa) manifold pressure, inlet pressure must be at
least 11" (2,7 kPa).
Leak testing of the appliance shall be conducted
according to the manufacturer's instructions, see step
4H.
The gas supply line should be ½" or ¾" I.D.
3

Seal the openings

Seal any openings in the fl oor under the appliance or in
the wall behind the appliance after the gas supply line
is installed.
Recommended hole
location for through the
wall gas entry line.
Figure 5a