Installation
Figure 2
Installation
Surface
6.7 in.
(170mm)
Air Inlet
DFI400: 100cm
DFI600: 150cm
New Construction
1. Mark the desired location on
the floor and store the fireplace
in a safe, dry and dust free
location.
2. Use studs to frame
sure with the following mini-
mum internal/opening dimen-
sions (Figure 2).
!
NOTE: An air inlet is required
for optimum mist production, see
Figure 2 for minimum dimen-
sions.
NOTE: For optimal perfor-
!
mance, the following minimum
clearances between the instal-
lation surface and any surface
above should be maintained:
• Cassette Only: 12 in. (305 mm)
• Cassette with Dimplex heater:
19 in. (483 mm)
2
2
an enclo-
DFI400: 15.75 in. (400mm)
DFI600: 22.05 in. (560mm)
Supports: 0.75 in (19 mm) high
Figure 3
üüü
(30.0 mm)
1.2 in.
(30.0 mm)
4.8 in.
(122.0 mm)
3.5 in.
(90.0 mm)
3. Secure unit through the two
holes in the bottom of the unit
into supports to prevent the
unit from hanging from the top
flange, see figure 3 for dimen-
sions.
4. The unit is equipped with a
power supply plug and a fused
receptacle (Figure 4), the plug
should be plugged
a 15 A, 120 V outlet.
CAUTION: During operation
Exit for Cord
5.4 in.
(137.0 mm)
3.1 in.
(80.0 mm)
FRONT
directly into
7