Hearth Stove
Positive
Connection
Hearth Stove Direct
Connection
NOTE:
This type of installation is
not allowed in Canada.
NOTE:
Direct connections require
installation of an airtight,
non-combustible block-off
plate or damper adapter.
© Travis Industries
Stove Installation
NOTE: The entire fireplace and
chimney must be clean, undamaged,
and meet all local building codes
(UBC, etc.). Damage must be
repaired prior to installation. The
chimney must be 15' to 33' tall.
Combustible
Mantle
Floor Protection
(See the section
"Floor Protection
Requirements"
for more details)
NOTE: The chimney must have a clay
tile liner. If it does not, the installation
must use a positive connection (full
reline). The entire fireplace and
chimney must be clean, undamaged,
and meet all local building codes (UBC,
etc.). Damage must be repaired prior
to installation. The chimney must be
15' to 33' tall.
Combustible Mantle
Floor Protection
(See the section "Floor
Protection Requirements"
for more details)
(for qualified installers only)
Min. 36"
Min. 36"
100-01164
17
Cap and flashing
prevents water from
entering
The liner must be
stainless steel connector
or flexible vent. Follow
the liner manufacturer's
instructions for installation
and support.
Airtight Insulated
Clean-Out
Remove damper
or wire it open
See the section
"Stove Placement
Requirements" for
minimum clearances
required.
Figure 15
Clay
Liner
Stainless steel
chimney connector
must Extend 1' past
the block-off plate or
to the flue liner
Airtight
Insulated
Clean-Out
Remove damper
or wire it open
Block-off plate or
damper adapter
See the section
"Stove Placement
Requirements" for
minimum clearances
required.
Figure 16
4110819