RIB S111 Instruction Pour Le Montage page 12

Coffret électronique pour la commande d'un moteur monophase ou triphase

Publicité

Les langues disponibles

Les langues disponibles

PLUG J2
2
- Stop push-button (n.c.).
K
- Single pulse contact (n.o.).
7
- Contact of the limit switch which interrupts closing (n.c.).
4
- Contact of the limit switch which interrupts opening (n.c.).
9
- Push-button opens (n.o.).
11
- Push-button closes (n.o.).
E
- Contact given by the safety devices in the opening phase (n.c.).
B
- Contact given by the safety devices in the closing phase (n.c.).
10
- Photo cells contact (n.c.).
8
- Common wire to the contacts and the push-buttons.
PLUG J3
RSTN
- 3 phase power supply (neutral must be connected).
SN
- Single/Phase power supply.
- Earth terminal.
PLUG J4
U1= Common wire. V1-W1= Inverters
U1-V1-W1
L-L
CONNECTOR J5
Contatto Termico
- For use when the termal relay is connected.
- The termal relay is supplied as standard in the version S112.
- Can also be used for the connection of the emergency button.
PLUG J6
Cambio Tensione
- For single phase connections see Fig. 2 (case 230V).
- For three phase connections see Fig. 2 (case 400V).
CONNECTOR J7
Connector for housing R.I.B. radio receivers.
PLUG J8
A*
- Common wire for power supply.
A
- 24VAC power supply for photo cells.
D+D-
- 12VDC power supply for accesssories.
SL
- Gate open light LED power supply.
1
- 12VAC electric lock power supply.
CHB
- Radio channel B contact output (n.o.).
CHC
- Radio channel C contact output (n.o.).
CONNECTOR J9
When it is in the "ON" position (dip-switch 8), it supplies a courtesy lamp for 3 minutes (max. 40W9 by means of an optional card (box auxiliary activation code
ACQ9070).
The green LED on the card signals that it is fed.
The red LED on the card signals the relay is enabled for the box light. In the "OFF" position (dip-switch 8), the optional card relay will give a 1 " pulse (examples of
applications: timed relay control, garden lights, access to garage, underground corridors, etc.).
N.B.: Do not insert the automatic closing timer on the card (ACQ9050), since the automatic closing function is managed by the microprocessor, see trimmer P3 or
the "automatic closing" paragraph.
PUSH-BUTTONS AND SELECTORS
Should there be two or more push-button panels, connect the opens and closes control (terminals 9 and 11) in parallel with one another and the stop contacts
(terminal 2) in series with one another.
Any key selectors must be connected between terminals 8-9-11.
If no stop push-buttons are scheduled, make a bridge between terminals 2 and 8.
PHOTO CELLS
The photo cells (inserted as in the fig. 2) make it possible to interrupt the movement of the operator both in the opening and in the closing phase (with movement
being reset at the end of the intervention).
See the UNI 8612 Regulations - point 5.1.4.1 - point 5.1.4.2.
Should the photo cells be damaged, if you give a gate movement command, the flashing light will not signal and the motors will remain stationary.
Operate dip-switch 1 to eliminate photo cell intervention during opening.
N.B.: If two or more pairs of photo cells are connected, connect the A*-A power supply in parallel to all the transmitters and receivers and connect terminals 8-10 in
series with one another.
RADIO
By making the contact given by the radio receiver relay (operating pin J7 between terminals 1-2), the gate is opened (if it is closed or in any position except at the
end of the opening cycle) and closed (only if the gate is open).
If the gate is moving and you intervene with the radio control, the first pulse you give will be Stop and the second will be consent for movement in the opposite
direction to the one it was moving in before it was stopped.
- For single phase motors.
- For 3 phase motors.
- Flashing light feed out-put (40W max.).