10 WIRING DIAGRAM

It is printed on a sticker in the engine compartment.

11 TROUBLESHOOTING GUIDE

PROBLEM
The appliance does not operate
Temperature inside the appliance is too cold
Temperature inside the appliance is too warm
/ Compressor seems to run too long
Popping or cracking when compressor comes
on
Bubbling or gurgling sound, like water boiling
Vibrations
POSSIBLE CAUSE
Not plugged in
The circuit breaker tripped or blown fuse
Compressor is out of order
Thermostat is not set correctly or is out of order
A large amount of warm / unfrozen products might have
been stored recently. Wait until the appliance reach its
selected temperature
The door(-rs) are not closed completely
The condenser is covered with dust and dirt (only for
condensers with aluminum sheets)
The outside temperature is hotter than normal
There is no enough air circulation space in front of engine
compartment openings
The condenser fan motor is out of order
The evaporator fan motor is out of order
Products are placed too close to evaporator fan
blade cover, blocking the air circulation
Ice has build-up on evaporator aluminum sheets
There is a refrigerant leakage in the circuit
This is normal. Sound will level off or disappear as the
appliance continues to run
This is normal. It becomes from the refrigerant circulating
The appliance is touching the wall.
Move it from the wall The appliance is not a level surface.