CLEARING CLOGGED TIP
a) Release trigger, put safety ON.
b) Rotate T93R Tip.
c) Take safety OFF
d) Trigger gun to clear clog. Never point gun at your hand or in a rag!
RETRUN TO SPRAY
a) Put Safety ON.
b) Return Tip to spray posiĦon.
c) Take safety OFF and conĦnue spraying.
CLEAN UP
1. Turn power OFF and unplug sprayer.
2. Turn pressure to lowest setĦng. Trigger gun to relieve pressure.
3. Put pressure relief tube in pail. Turn pressure relief valve down.
4. Remove guard and T93R Ħp. Clean �p with soŌ bristle brush. DO NOT STORE IN WATER.
5. Remove siphon tube set from paint and place in flushing fluid. Use water for water base paint and mineral spirits
for oil base paint.
6. Plug in sprayer. Turn power ON. Return Pressure relief valve to its horizontal posiĦon.
7. Hold gun against paint pail. Take trigger safety OFF. Trigger gun and increase pressure unĦl flushing fluid
appears.
8. Move gun to flushing pail, hold gun against pail. Trigger gun to thoroughly flush system. Release trigger and put
trigger safety ON.
9. Turn pressure relief valve down and allow flushing fluid to circulate for 1 to 2 minutes to clean drain tube.
10. Raise siphon tube above flushing fluid and run sprayer for 15 to 30 seconds to drain fluid. Turn power off.
11. Close pressure relief valve. Trigger gun into flushing pail to purge fluid from hose.
12. Turn pressure relief valve down to insure there is no pressure in the unit. Then retrun pressure relief valve to
its horizontal posiĦon. Do not store with pressure relief valve down.
13. Remove filter from gun and sprayer, if installed. Clean and inspect. Reinstall filters.
14. If flushing with water, flush again with mineral spirits or TriTech Pump Cleaner to leave a protecĦve coaĦng to
prevent freezing or corrosion.
15. Unplug power cord from outlet and wipe sprayer, hose and gun with rag soaked in water or mineral spirits.
8