Installation
11. Clean sealing surface and groove of cover
flange; place on tank (see Figure 5). Be sure to
capture the base with the flange (the tabs on the
base fit the notches on the flange).
NOTICE: Be sure discharge port lines up with
hole in base.
Water
Cell
Base
Cover Flange
Figure 5 – Proper installation and
seating
12. NOTICE: Tighten nuts as follows:
A. Hand tighten all nuts.
B. Tighten one nut snug.
C. Tighten opposite nut snug.
D. Proceed, tightening opposite pairs of nuts to
a snug fit.
SUBMERSIBLE AND MULTI-STAGE INSTALLATIONS
Tank with Submersible Pump
Pressure
Pressure
Gauge
Switch
From Well
Tank
Wall
3947 0401
PIPING CONNECTIONS
NOTE: When using metal pipe with plastic fittings use only
PTFE pipe thread sealant tape on male threads.
To service
Pressure
Relief Valve
E. Recheck all nuts, using same pattern. Be sure
all nuts are tight and that you have a good
seal.
NOTICE: Do not overtighten; you may
twist studs off of tank. If you have a torque
wrench, tighten to 85 inch-pounds torque.
13. Stand tank on feet and reconnect piping.
14. Recharge tank to proper air pressure (see
Page 4).
15. Prime pump (see pump owner's manual).
AIR VALVE REPLACEMENT
valve and core cannot blow out of tank, release all
air pressure from tank before removing valve core
or valve.
1. Disconnect power to pump.
2. Drain ALL water in system by opening faucet
closest to tank.
3. Depress valve core to release ALL air pressure
in tank. When air stops coming out of valve,
remove core from inside of valve to release
remaining pressure.
4. Unscrew valve from tank and install new valve.
Do not overtighten.
5. Recharge tank (see Page 4), turn on power, fill
system, and tank is ready for service.
Tank with Multi-Stage Pump
Pressure
Relief Valve
160 0893
Hazardous Pressure. To be sure air
To Service
6