B. Reconnect power supply to pump and pump
up pressure in system.
C. Disconnect power supply to pump again and
re-check switch setting.
D. Repeat until pressure switch starts pump
within ±1 PSI of proper setting.
E. If cut-in setting is too low, system will rattle
or develop water hammer when pump starts.
F. Cut-out setting is not as critical as cut-in set-
ting. Make sure that pump will stop running
in a rea son able time. If it does not, cut-out
setting may need to be adjusted down slight-
ly. Be sure that after readjustment, system
does not rattle or hammer on startup.
7. Re-check tank air pre-charge to be sure it is 2
PSI below pump pressure switch cut-in setting
(see Page 3).
TESTING FOR WATER CELL
LEAKAGE
1. Disconnect power to pump.
2. Drain all water from tank water cell by opening
faucet closest to tank.
3. Remove valve cap from valve and release all
pressure possible by depressing valve core.
When air stops coming from valve, remove
valve core to release remaining pressure.
4. Disconnect piping from elbow on tank flange.
5. Carefully turn tank upside down or lay it on its
side.
Retained water in tank may
cause sudden weight shift when lowering.
Support tank so that it cannot fall when being
lowered or inverted.
6. If water cell leaks, water will run out of valve. If
so, replace water cell.
WATER CELL REPLACEMENT
To be sure cover flange cannot
blow off of tank, release all air from system before
re moving nuts from cover flange.
1. Disconnect power to pump.
2. Follow steps 2 through 5 under "Testing For
Water cell Leakage", above.
3. Remove nuts from tank cover flange. Tap cover
flange to break seal and remove. Base will
come off with flange.
4. Water cell will not come out in one piece.
Hold water cell with pliers and cut wherever
convenient with single edge razor blade or
sharp knife. Continue holding and cutting until
water cell is removed.
5. Clean and dry inside of tank.
6. Before water cell can be inserted into tank, it
must be tightly rolled up as follows:
A. Place water cell on clean surface with open-
ing to one end and flatten to force air out.
Pull ends out flat (see Figure 3).
Pull ends out flat
Figure 3 – Force all air out of water
cell
B. To get tightest possible wrap, start on one
side at top and TIGHTLY roll water cell
diagonally to other side (see Figure 4). To
force out as much air as possible, be sure to
roll toward water cell neck opening.
Roll Diagonally
Figure 4 – Roll diagonally toward neck
7. To help insert water cell, sprinkle outside of it
with talcum powder. With tank on its side, push
tightly rolled water cell into tank, hooking water
cell neck ring over edge of tank head.
8. Insert arm in water cell and push sidewalls
outward. It is not necessary to remove all
wrinkles from water cell.
NOTICE: Don't push water cell into tank further
than its own length. In a large tank, water cell
can slip out of reach if pushed too far.
9. Clean tank head sealing surface and lip ring
groove of cover flange.
10. Pull lip ring of water cell through tank opening
and seat it against tank head.