..28 ..35 Frico AB certifies that PAEC4000W, PAEC4000E and PAEC4000A shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
Page 2
PAEC4000 Metric chart 1 Ambient, no heat - PAEC4000A (IP21) Type Output Airflow* Sound Motor Voltage Amperage Weight power* power motor motor [kW] [dB(A)] [kg] PAEC4010A-NA 2330 208V1~ PAEC4015A-NA 3270 208V1~ PAEC4020A-NA 4650 1000 208V1~ PAEC4025A-NA 5600 1173 208V1~ 3 Electrical heat - PAEC4000E (IP20) Type Output Airflow*...
Page 3
Uniformity [%] Uniformity [%] Frico AB certifies that PAEC4000W, PAEC4000E and PAEC4000A shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
Page 4
PAEC4000 Imperial chart 1 Ambient, no heat - PAEC4000A (IP21) Type Output Airflow* Sound Motor Voltage Amperage Weight power* power motor motor [MBH] [cfm] [dB(A)] [lb] PAEC4010A-NA 1400 208V1~ PAEC4015A-NA 1950 208V1~ PAEC4020A-NA 2800 1000 208V1~ PAEC4025A-NA 3300 1173 208V1~ 3 Electrical heat - PAEC4000E (IP20) Type Output...
Page 5
Uniformity [%] Uniformity [%] Frico AB certifies that PAEC4000W, PAEC4000E and PAEC4000A shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
Page 6
PAEC4000 Output charts water PAEC4000 Metric chart Supply water temperature:80 °C Water temperature: 80/60 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +35 °C* Type Airflow Output Return Water Pressure Output* Outlet Water Pressure position water flow drop air temp.
Page 7
PAEC4000 The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages. Les pages de présentation contiennent principalement des images. Pour la traduction des textes en anglais, consultez la page correspondante à la langue souhaitée.
Page 8
PAEC4000 PAEC4000 DN20 (3/4"), outside thread A / B / C / D PAEC 2; 2.5 m / 6.6; 8.2 ft E / F Ref Metric Imperial Product type [mm] [in] 1039 41.56 PAEC4010x 1549 61.96 PAEC4015x 2039 81.56 PAEC4020x 2549 101.96 PAEC4025x...
Page 9
PAEC4000 Fig. 1A: Open the unit by raising the front panel. Fig. 1B: When the front has been removed it it The front is blocked in open position with the important to be sure it is firmly seated in the front front hatch hook.
Page 10
PAEC4000 PAEC4010x/PAEC4015x D / E Metric Imperial Product type [mm] [in] 5.08 PAEC4010/15/20/25x 4.08 PAEC4010/15/20/25x 9.40 PAEC4010/15/20/25x 30.00 PAEC4010x 1260 50.40 PAEC4015x 35.00 PAEC4020x 29.80 PAEC4025x 30.80 PAEC4025x PAEC4020x PAEC4025x Fig. 5: M8-holes for mounting.
Page 12
PAEC4000 Accessories PA34CB PA34TR PA34WS (PA34VD) (PA34CB) Fig. 7: PA34TR + PA34CB + PA34VD. Fig.8: PA34WS + PA34CB See separate manual for PA34TR. See separate manual for PA34WS. Type Product type Quantity Length Length included Metric Imperial PA34CB15 PAEC4010/15x 4 pcs PA34CB20 PAEC4020x 6 pcs...
Page 13
PAEC4000 Accessories Type Product type Length Length Metric Imperial [mm] [in] PA4XT10 PAEC4010x 130-200 5.20-8.00 PA4XT15 PAEC4015x 130-200 5.20-8.00 PA4XT20 PAEC4020x 130-200 5.20-8.00 PA4XT25 PAEC4025x 130-200 5.20-8.00 Fig. 10: See separate manual for PA4XT. Type Product type Dimensions Dimensions PA4DW Metric Imperial [mm]...
Page 14
PAEC4000 Accessories Note! The air curtain must be secured in the wall or ceiling. PA4VDW PA4JK Fig. 11: See separate manual for PA4JK.
Page 15
PAEC4000 Accessories PA4HE(VDW) PA4JK PA4VDW AXP300 Type Product type PA4JK PAEC4000 PA4VDW15 PAEC4015x PA4VDW20 PAEC4020x PA4VDW25 PAEC4025x PA4HE PAEC4000 PA4HEVDW PAEC4000 AXP300 PAEC4000 See separate manual for DTV200S See separate manual for PA34EF. FHDN20. Type Product type Length Length Metric Imperial PA34EF10 PAEC4010W...
Page 16
PAEC4000 Accessories SIReACY SIReRTX SIReWTA SIReCJ4/SIReCJ6 SIReCC SIReAAY Type Dimensions Length Dimensions Length Metric Metric Imperial Imperial SIReACY SIReAAY SIReRTX 70x33x23 mm 2.80x1.32x0.92 in SIReWTA SIReCJ4 SIReCJ6 SIReCC603 9.8 ft SIReCC605 16.4 ft SIReCC610 10 m 32.8 ft SIReCC615 15 m 49.2 ft SIReCC640 40 m...
Page 22
PAEC4000 • Read the safety instructions before performing installation and/or maintenance activities on the unit. • Installation and/or maintenance activities on the unit may only be performed by qualified technical staff. • The unit shall not be installed and used outdoors or in environments that are aggressive, or potentially explosive.
Page 23
PAEC4000 Consignes de montage et mode d'emploi Généralités Montage Lisez attentivement les présentes consignes Les rideaux d'air sont prévus pour une avant d'installer et d'utiliser l'appareil. installation verticale ou horizontale. Les Conservez ce manuel afin de pouvoir le appareils peuvent également être encastrés en consulter ultérieurement.
Page 24
PAEC4000 Montage vertical PA4JK Appareil avec chauffage électrique Le raccordement électrique s'effectue sur Les appareils mesurant 1.5 mètre/4.9 pieds et la partie supérieure de l'appareil. Voir Fig.2. plus peuvent être utilisés à la verticale. Pour 208V3~/ 480V3~/ 600V3~ commande et pouvoir être montés verticalement, tous les puissance (*1 *2) doivent être connectées appareils doivent être équipés d'un kit de...
Page 25
élevée, plus l'angle doit être important. un circuit ouvert. Noter que l'appareil doit être précédé d'une vanne de régulation ; voir le kit de vannes Frico. Réglage initial de la vitesse de La batterie à eau chaude est connectée à...
Page 26
PAEC4000 Entretien Commande de la température Appareil avec chauffage à eau chaude La régulation de température SIRe maintient la Le filtre doit être nettoyé régulièrement pour température d'échappement. Si, malgré tout, garantir l'effet rideau d'air et l'émission de la température dépasse la valeur prédéfinie, chaleur.
Page 27
PAEC4000 Sécurité • Un disjoncteur à courant résiduel de 300 mA Pour les appareils à chauffage électrique, contrô- doit être utilisé contre les risques d'incendie ler également les points suivants : dans les installations de produits avec • Alimentation électrique de la résistance : chauffage électrique.
Page 28
PAEC4000 Traduction des pages de présentation • Outside thread Filetage extérieur Quantité inclue • Quantity included • pcs Pièces • Accessories Accessoires • See separate manual for xxx Voir le manuel de la référence XXX. • Wiring diagrams for XXX and XXX, Schémas de raccordement pour xxx et xxx, voir le manuel de la référence SIRe.
Page 29
Uniformity Uniformité Frico AB certifie que les rideaux d'air PAEC4000W, PAEC4000E et PAEC4000A présentés ici sont autorisés à porter le sceau AMCA. Les cotes de performance indiquées sont basées sur des tests et des procédures exécutés conformément à la publication AMCA 211 et à la publication AMCA 311 et sont conformes aux exigences du programme de classification certification AMCA.
Page 32
Main offi ce Frico AB Tel: +46 31 336 86 00 Industrivägen 41 SE-433 61 Sävedalen mailbox@frico.se Sweden www.frico.net For latest updated information and information about your local contact: www.frico.net...