Chamberlain B2202C Manuel D'installation page 28

Masquer les pouces Voir aussi pour B2202C:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation
STEP 14 Wire the Safety Reversing Sensors (continued)
OPTION B - PRE-WIRED INSTALLATION
1.
Cut the sensor wires, making sure there is enough wire to reach the pre-installed wires from the wall.
2.
Separate the sensor wires and strip insulation from each end. Choose two of the pre-installed wires
and strip insulation from each end. Choose the same color pre-installed wires for each sensor.
3.
Connect the pre-installed wires to the sensor wires with wire nuts making sure the colors correspond
for each sensor.
4.
At the garage door opener, strip the end of the wires previously connected to the sensors. Twist the
like-colored wires together.
5.
Using a screwdriver, push in the terminal tabs, and insert the wire color connected to the sensor's
white wire into the white terminal. Insert the other wire color connected to the sensor's white/black wire
into the grey terminal.
1
Pre-installed
wires
Safety reversing sensor wires
3
Safety reversing
sensor wires
White
White/Black
Pre-installed wires
4
Yellow
Purple
7/16" (11 mm)
28
2
7/16" (11 mm)
Wire nuts (not provided)
Pre-installed wires
Yellow (for example)
Purple (for example)
5
Purple
Yellow

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

B2405cB4505tc

Table des Matières