POWER
Speed adjustable
1
2
INFO
POWER
Speed adjustable
1
2
INFO
POWER
Speed adjustable
2
1
INFO
After a voltage drop the pump automatically starts up again with the speed last set,
or remains stopped if it had been stopped beforehand.
Overview of possible operating and error messages
If an error occurs, the motor switches off permanently and a message is displayed.
Exception: "Undervoltage" at a failure or switching-off of the power supply. At this fault
the drive starts again when the supply voltage is switched on again.
If an error occurs, the system must be disconnected from the power supply. See
Chapter 2.2 of the original Operating Manual "Non self-priming and self-priming
pumps with/without plastic lanterns (AK version)".
18 EN
VG 766.2100.071
 
3
S
0
 
 
 
3
S
0
 
 
 
3
S
0
 
 
Switching behaviour "0" (stop)
The switching behaviour of the digital input "0"
can be changed (inverted) by using the menu
item "0".
"cL" means that the drive is stopped at a
closed contact.
"oP" means that the drive is stopped at an
open contact.
Resetting
The drive is reset to the factory setting when
the "INFO" button is pressed for at least 10
seconds. The motor stops and "rESEt" is
displayed.
The current required power of the pump is
shown in watt (P XXX) in the display when the
"INFO" button is pressed.
The display of the control unit switches off
after three minutes without action.