TECHNICAL DATA
Power supply
Output supply
Power maximum motor
Output supply accessories
Protection level
Operating temp.
Radio receiver
Rolling code transmitters supported
Terminal No.
Function
1-2
Power supply
3
GND
4-5
Aerial
8-9
24Vac
SCA o
10-11
Service light
12-13
PHOTO TEST
14
COM
15
OPEN
16
CLOSE
17
Step-by-Step
18
PED
19
COM
20
STOP
21
PHOT O
22
SWO
23
SWC
24
PHOT C
25-26
DAS
230 Vac 50/60 Hz
1 motor 230Vac
1000 W
24Vdc 500mA max.
IP54
-20°C / +70°C
433.92 MHz, built-in and configurable
(rolling-code or fixed+rolling-code+ ARC Advanced Rolling Code)
64
CP.BISON OM CONTROL UNIT
INPUT/OUTPUT FUNCTIONS
Description
Input, 230Vac 50Hz (1-Phase/2-Neutral)
Ground connection. Use the connector preset on the fitting plate of the control unit.
Earthing is COMPULSORY, through this connection also the metal structure of motoriza-
tion are grounded.
Connection of the insertable radio receiver card (4-signal/5-display).
Output, power supply of accessories, 24VAC/1A max
Normally Open clean contact, configurable as SCA (open gate light), timed service light (see
SERL Logic) or as second radio channel (see Logics 2 Ch).
N.O. free contact. It is used to power photocell transmitters in TEST operating mode.
See diagram Fig.3 and TST1 and TST2 Logic.
Common for control inputs.
Input, push-button for OPEN contact (Normally Open contact) Contact usable for timed open-
ings through timer.
Input, CLOSE push-button (N.O. contact)
Input, step-by-step push-button (N.O. contact)
Input, pedestrian push-button (N.O. contact). It controls the partial opening. Configuration is
through parameter TPED. When TCA time has elapsed (if activated) a closure control signal is
sent.
Common, for limit switches and safety devices
Input, STOP push-button (N.C. contact)
Input, (N.C. contact) for safety devices (e.g. photocells).
In the closing phase: the contact opening causes the motor stop. Common: when the photocell
is released, the motor inverts the movement direction (open).
In the opening phase: the contact opening causes the motor stop. When the photocell is re-
leased, the motor re-starts the opening operation.
Input, OPEN limit switch (N.C. contact)
Input, CLOSE limit switch (N.C. contact)
Input (N.C. contact) for safety devices (e.g. photocells).
In the closing phase: Configuration through PHCL Logic.
In the opening phase: Configuration through PHC Logic.
Input, safety edge
Resistive edge: "DAS" Jumper closed
Mechanical edge: "DAS" Jumper open
When the edge is activated, the gate movement is stopped and reversed for about 3s.
If the edge is not in use: "DAS" Jumper open, 25-26 terminals are short-circuited.