Pre-Start Checks

Inspection prior to start-up
The following inspection must be performed before the start of each work session or after every four
hours of use, whichever is first. Please consult the service section for detailed guidance. If any fault is
discovered, the 'VR-Roller' must not be used until the fault is rectified.
1. Thoroughly inspect the machine for signs of damage.
2. Check hoses, filler openings, drain plugs and any other areas for signs and leakage. Fix any leaks
before operating.
3. Check the engine oil level and top up if required. When checking the oil make sure the machine is
on a level surface. To check the oil level, remove the oil guage and observe the oil level; it should
be up to the rim of the filler port. Ensure proper engine oil with the correct viscosity is used (SAE
10W-30 is recommended).
4. Check the engine fuel level and top up if required. Use clean fuel! The use of contaminated fuel
may damage the fuel system.
5. Check the air filter is clean. Excessive dirt/dust accumulation within the filter element will cause
erratic engine operation. Clean the air filter element if it is contaminated (refer to the 'Service and
Maintenance' section).
6. Check the Operator's Controls are in good working order. Ensure that the Drive Lever, the
Vibration Lever, the Throttle Lever, the Parking Lever, and the safety device for the reverse
motion all move smoothly.

Start and Stop Procedure

DO NOT let go of the Starting Handle during the starting procedures. Ensure
you keep a firm hold.
CAUTION
Before starting the engine, make sure the Drive Lever is in the Neutral position, the Vibration Lever is
in the OFF position and the Parking Lever is in the ON position.
1. Open the fuel tap at the engine.
2. Move the Throttle Lever at the Operation Handle to START position.
3. Start the Engine – Electric Start
3a. Turn the Key Switch at the Throttle Lever to ST (Start) position, and
hold it until the engine starts.
3b. When the ambient temperature is low, move the key to GL (Glow)
position and hold it for approximately 10 seconds. Then move the Key to ST (Start) position and
hold it until the engine starts.