Télécharger Imprimer la page

Honeywell LUTRON TouchPRO Wireless Guide D'installation page 3

Publicité

Les langues disponibles

Les langues disponibles

Battery Replacement
The TouchPRO Wireless® thermostat has
a coin cell battery that retains the time and
date during a power failure. Under normal
circumstances the coin cell should last
five years. Should the time and date need
to be reset after a power failure, this is an
indication that the coin cell needs to be
replaced. You should replace the battery
every five years, or before leaving home for
an extended period.
To replace the battery, remove the battery tray using a screw driver. Place a new coin cell (type
CR2032 or equivalent) observing the correct polarity and push the battery tray into the battery
cover assembly.
Power Requirements
E/AUX
K
K
S1
S1
S2
S2
Connect the common side of the
transformer to "C" terminal. This
connection is mandatory.
Wiring
Remove factory-installed jumper only
for two-transformer systems.
W2
E/AUX
K
K
S1
S1
S2
S2
P/N 041-338 Rev. C
Coin cell
battery tray
Remove tab.
M32688
The TouchPRO Wireless® thermostat is shipped from
the factory with the coin cell installed. To keep the
battery from discharging during shipment and storage,
the TouchPRO Wireless® thermostat is shipped with a
plastic tab inserted in the battery holder. This tab must
be removed during installation. Simply pull the plastic
tab out of the battery tray. Make sure that the battery
tray is fully inserted into the TouchPRO Wireless®
thermostat.
Push excess wire back into the wall opening. Plug
wall opening with non-flammable insulation.
M32689
3
TouchPRO Wireless
M32680
M32690
69-2655EFS—05
®

Publicité

loading

Ce manuel est également adapté pour:

Lr-hwlv-hvacLutron lr-hwlv-hvac touchpro wireless