G
B
J1
N -L1
Main power supply 230 Vac 50/60 Hz (120V/60Hz upon request)
J2
A+ TEST
Safety strip self-test power supply +24 Vdc
A +
Accessories power supply +24 Vdc
A -
Accessories power supply -24 Vdc
PHOT. NC
Photocells contact (NC)
EDGE NC
Safety strip contact (NC)
K BUTT.
Single pulse contact (NO)
PED. BUTT.
Pedestrian opening contact (NO)
COM
Common contact (common line for all the command and safety
inputs)
LOCK
Electric lock connection (MAX 15W 12V)
AERIAL
Radio Antenna
J3
COM
Common contact (common line for all the command and safety
inputs)
BUZZER
Buzzer contact (24 Vdc max 200 mA)
SIGNAL
Gate open state output indicator (24 Vdc 3W max)
J4
Flashing light (max 40W )
U - MOTOR 2
MOTOR 2 COMMON CONNECTION
V-W - MOTOR 2 MOTOR 2 PHASE AND CAPACITOR CONNECTIONS
U - MOTOR 1
MOTOR 1 COMMON CONNECTION
V-W - MOTOR 1 MOTOR 1 PHASE AND CAPACITOR CONNECTIONS
J5
DO NOT REMOVE ANY JUMPER! OTHERWISE THE OPERATOR
WILL NOT WORK!
SW T2
J6
SW RADIO
(only CRX control board) DO NOT REMOVE ANY JUMPER!
OTHERWISE THE OPERATOR WILL NOT WORK!
J7
PROBE
Terminal block to connect the heater sensor only for operator
(code AA14019).
J8
RADIO
Built-in radio module (model CRX), or connector for radio receiver
RIB, 24 Vdc supply
POINT B - SETTINGS
DIP 1
(ON) MOTOR ROTATION DIRECTION CHECK (See Point C)
DIP 2
(ON) PROGRAMMING (See Point D)
DIP 1-2 STORAGE/DELETION OF RADIO CODES FOR COMPLETE
OPENING (DIP 1 ON followed by DIP 2 ON) (POINT G) ONLY FOR CRX MODELS
DIP 1-3 STORAGE/DELETION OF RADIO CODES FOR PEDESTRIAN OPENING (DIP 1 ON
followed by DIP 3 ON) (POINT H) ONLY FOR CRX MODELS
DIP 2-1 PROGRAMMING OF THE PEDESTRIAN OPENING (See Point F)
DIP 3
ON - Automatic Closing ENABLED
OFF - Automatic Closing DISABLED
DIP 4
ON - Photocells active only in closing
OFF - Photocells always active
DIP 5
ON - blinker pre-flashing
OFF - blinker normal-flashing
DIP 6
OFF - STEP BY STEP
Single pulse contact (K BUTT)
Pedestrian button (PED BUTT)
Radio Receiver command
ON - AUTOMATIC
Single pulse contact (K BUTT)
Pedestrian button (PED BUTT)
Radio Receiver command
DIP 7
ON - low speed in approaching ENABLED
OFF - low speed in approaching DISABLED
DIP 8
ON - electric lock command ENABLED
OFF - electric lock command DISABLED
DIP 9
ON - Hammering on complete close position to ease Manual Release
- Hammering before opening to ease electric lock unlocking
OFF - no impulse
DIP 10
ON - Extra thrust when reached closing position to make sure that the mechanical
bolt is fixed into the ground
OFF no impulse
POINT A - CONTROL PANEL FEATURES
TR2
TR1
S3
J8
J5
JP1
JP2
JP3
J6
J3
J7
J2
JP17
To select 1 motor (M1) or 2 motors (M1 and M2)
S3
PROG
Programming button
TR1
TORQUE
Electronic torque regulator
TR2
LOW SPEED
Electronic regulator for low speed on approach motor (See chart
1)
DIP 11
ON - black out function ENABLED (See chart 2)
OFF - black out function DISABLED
DIP 12
ON - close command after the transit through the photocell ENABLED
OFF - close command after the transit through the photocell DISABLED
DIP 13
ON - safety strip self-test ENABLED
OFF - safety strip self-test DISABLED
DIP 14
to select type of motor (see CHART 1)
DIP 15
to select type of motor (see CHART 1)
DIP 16
to select type of motor (see CHART 1)
JP 17 OPEN JUMPER 1 motor (M1) - 1 leaf
CLOSE JUMPER 2 motors (M1 and M2) - 2 leaves
JP1 => Pay attention that the jumper is inserted!
JP2 => Pay attention that the jumper is inserted!
JP3 => Pay attention that the jumper is inserted!
TYPE OF MOTOR
1
KING 230/50
KING L 230/50
KING 220/60
KING L 220/60
KING ICE 230/50
22
JP17
ON
CHART 1
CODE
DIP 14
DIP 15
AA14001
OFF
OFF
AA14010
AA14002
AA14011
AA14019
J4
J1
DIP 16
OFF