Diagrammatical Representation of Outdoor Areas
•
This appliance shall only be used in an above ground open-air situation with natural ventilation,
without stagnant areas, where gas leakage and products of combustion are rapidly dispersed by wind
and natural convection.
•
Any enclosure in which the appliance is used shall comply with one of the following: An enclosure
with walls on all sides, but at least one permanent opening at ground level and no overhead cover.
Within a partial enclosure that includes an overhead cover and no more than two walls.
Within a partial enclosure that includes an overhead cover and more than two walls, the following
shall apply:
(i)
at least 25% of the total wall area is completely open; and
(ii)
at least 30% of the remaining wall area is open and unrestricted.
In the case of balconies, at least 20% of the total of the side, back and front wall areas shall be and
remain open and unrestricted.
• Outdoor Area - Example 1
• Outdoor Area - Example 2
4