Gas Safety Information
The appliance must be installed at least 3.5ft (1 meter) from any flammable materials.
The oven should be placed on a non-flammable, stable and flat surface.
Make sure your oven is placed in an area that will not be affected by adverse weather.
When the diameter of the injector is 0.83mm use the provided 11 WC (28mbar) regulator with Propane
LPG cylinder.
An LPG cylinder shall be of a maximum nominal 20 lb (9.1 kg) fuel capacity.
Use a suitable provided regulator certified to ANSI Z21.18/CSA 6.3 and a flexible hose certified to ANSI
Z21.54/CSA 8.4.
The regulator shall be installed in such a location that it will not attain a temperature above 130°F (54.5°C)
The length of the hose must be no more than 2 ft (61cms). Worn or damaged hose must be replaced.
Ensure that the hose is not obstructed, kinked, or in contact with any part of the oven other than at its
connection.
The gas supply hose should be checked periodically and should be replaced if damaged and at least
every two years.
Check all connections for gas soundness.
Your country's national requirements will advise you how often to replace the hose. Regularly review
these requirements for your country.
In the case of blocked venturi immediately turn off burner unit, turn off gas supply, disconnect gas supply
and wait until cooled to removed from oven.
Ensure the appliance is clear of debris before every use. If any debris does build up use a brush to remove
this when appliance has cooled.
USA / CAN
QCC1 gas regulator
This is a clockwise threaded gas fitting.
Ensure the tank is fully turned off and
screw the regulator on to the gas tank
valve fitting until tight.