Page 2
Always close the gas valve during the 5 minute waiting period. If Uuni 3 Gas Burner FSD at ooni.com does not ignite with the valve open, gas will continue to flow out of Uuni 3 Gas Burner FSD and could accidentally ignite with risk of injury.
• BEFORE USE CHECK APPLIANCE AND CONNECTIONS FOR LEAKS: You shall use your Uuni 3 Gas Burner FSD attachment part, in connection with your Uuni Never check for leaks with a naked flame, always use a soapy water solution. 3 oven, only with pre-bottled LPG (propane).
Page 4
Uuni 3 Gas Burner Diagrammatical Representation of Outdoor Areas Parts required: Uuni 3 Gas Burner FSD Gas hose Install hose pipe Tools required: Wrench x2 USA / CAN • Outdoor Area - Example 1 • Outdoor Area - Example 2 tighten with suitable wrenches •...
Page 5
Step 1 Parts required: Assembled Uuni 3 Remove the door and fit with Uuni 3 Gas Burner FSD chimney cap tighten with suitable wrenches Warning The door should removed at all times during use with the Uuni 3 Gas Burner FSD...
Page 6
Step 2 Step 3 Parts required: Parts required: Assembled Uuni 3 Assembled Uuni 3 Remove pellet burner Allen key Install Uuni 3 Gas Burner FSD Uuni 3 Gas Burner FSD...
Page 7
USA / CAN Step 4 Parts required: Assembled Uuni 3 Secure Uuni 3 Gas Burner FSD with Uuni 3 Gas QCC1 gas regulator Burner FSD Allen key This is a clockwise threaded gas Gas bottle fitting. Ensure the tank is fully...
Page 8
Step 5 Parts required: Assembled Uuni 3 with Uuni 3 Gas Igniting your burner POL gas regulator Burner FSD Push in and slowly turn the control knob This is an anticlockwise threaded anticlockwise until you hear a click and the gas fitting.
Page 9
If not, turn off the gas and go back to Step 5 Turn the gas on and light using a match and If Uuni 3 Gas Burner FSD still does not ignite the supplied match holder through the front go to Step 7...
Ooni Pro avec le et de provoquer une fuite. N’essayez jamais Brûleur à gaz Uuni 3 FSD tant que votre four Ooni de connecter votre Brûleur à gaz Uuni 3 FSD Pro n’a pas fait l’objet d’un test d’étanchéité au WARNING: au système autonome GPL d’une caravane ou...
Page 11
Uuni assemblé avec le bruleur à gaz Uuni 3 FSD doit être approuvé et conforme aux codes locaux. stockée à proximité de votre four Ooni Pro ou de doivent pas être manipulées par l’utilisateur. La longueur du tuyau ne doit pas dépasser 1.5 m Mise en garde: La trappe doit être retirée en tout...
Page 12
Assurez-vous que votre four soit placé dans une Si ce n’est pas le cas, couper l’arrivée du gaz et pizza que lorsque le Brûleur à gaz Ooni-Pro est zone qui ne sera pas affectée par les intempéries. zone qui ne sera pas affectée par les intempéries.