Contents
-
-
EC Declaration of Conformity
No. (S-No.):
71038
CPHL 400
71076
CPHL 400TP
according to EC directive 2006/42/EC
We,
Altrad Lescha GmbH
Josef-Drexler-Straße 8 - 89331 Burgau - Germany
herewith declare under our sole responsibility that the product
Baukreissäge (construction circular saw)
CPHL 400, CPHL 450, CPHL 500
Serial number: see last page
is conform with the above mentioned EC directives as well as with the
provisions of the guidelines below:
2004/108/EC, 2000/14/EC and 2011/65/EU
Following harmonized standards have been applied:
EN 1870-19
Conformity assessment procedure: 2000/14/EC - Appendix V
Measured level of the acoustic output L
Guaranteed level of the acoustic output L
EC type examination carried out by :
Prüf- und Zertifizierungsstelle Holz im DGUV Test - Vollmoellerstraße 11 -
70563 Stuttgart - Nr.: 0392
Certificate no.: HO 141118
Duly authorised person for the complilation of technical documents:
Altrad Lescha GmbH - Josef-Drexler-Straße 8 - 89331 Burgau - Germany
i.A.
Burgau, 06.01.2015
i.A. G. Koppenstein,
71045
CPHL 450
71052
CPHL 500
= 109,6 dB(A)
WA
= 110 dB(A)
WA
Engineering design management

Extent of delivery

1 Construction circular saw
1 Parallel limit stop
1 Pushstick
Assembly accessories for saw blade change
Operating manual
Check the machine for:
12
That it is complete
Check for possible transport damage
12
12
Report any damage or missing items to your dealer, supplier or the
manufacturer immediately. Complaints made at a later date will not be
12
acknowledged.
12
13

Characteristics noise values

13
13
EN ISO 3744:1995 / EN ISO 11202:1995/AC:1997 /
13
ISO 7960:1995 Appendix A, A.2 b)
14
Application of the machine as construction circular saw with standard saw blade.
15
Guaranteed sound power level L
16
Sound pressure level at the workplace
18
18
The factor of measurement uncertainty is K = 4 dB.
18
The values given are emission values and must therefore not simultaneously represent
19
safe workplace values too. Although there is a relationship between emission and
19
immersion levels, it can be reliably deduced whether additional precautionary measures
19
are necessary or not. Factors, which can influence the immersion level currently
existing at the workplace include the duration of the effects, the special type of the
19
workroom, other noise sources, etc. e.g. the number of machines and other adjacent
20
processes. The permissible workplace values can also vary from country to country.
This information should however enable an improved assessment of the danger and
20
risk to be carried out.

Operating times

Before initiating the device please observe the provisions pertaining to
corresponding laws (regional provisions) for the noise control.

Symbols machine

Carefully read opera-
tor's manual and the
safety instructions be-
fore starting the machine
and observe the
instructions when
operating.
Wear ear protection!
Electrical devices do not go into the domestic rubbish. Give
devices, accessories and packaging to an eco-friendly recycling.
According to the European Directive 2012/19/EU on electrical
and electronic scrap, electrical devices that are no longer
serviceable must be separately collected and brought to a facility
for an environmentally compatible recycling.
Symbols operating instructions
Threatened hazard or hazardous situation. Not observing this
instruction can lead to injuries or cause damage to property.
Important information on proper handling. Not observing this
instruction can lead to faults.
User information. This information helps you to use all the
functions optimally.
= 114 dB (A)
WA
No-load L
= 92.8 dB (A)
PA
Load L
= 98.5 dB (A)
PA
Shut off engine and
remove power cord
before performing
cleaning, maintenance or
repair work.
12