PROBLEMS
(SYMPTOMS)
Arc is unstable - Poor starting.
Error Code
003,010,013 Is displayed on
screen
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
Observe all Safety Guidelines detailed throughout this manual
POSSIBLE
1. Check for correct input voltage
to machine.
2. Check for proper electrode
polarity for process.
3. Check gun tip for wear or
damage and proper size -
Replace.
4. Check for proper gas and flow
rate for process. (For MIG
only.)
5. Check work cable for loose or
faulty connections.
6. Check gun for damage or
breaks.
7. Check for proper drive roll ori-
entation and alignment.
8. Check liner for proper size.
1. Communication error between
display P.C. board and power
control board.
CAUSE
If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized
Field Service Facility.
1. Cycle power to machine
2. Contact your local Lincoln
CAUTION
28
TROUBLE SHOOTING
RECOMMENDED
COURSE OF ACTION
Authorized Field Service Facility.