Specifications

Item
Model Name
Type
Ignition
Operating Pressure
Minimum Flow Rate
Dimensions (Height) x (Width) x (Depth)
Weight
Water Holding Capacity
Connection Sizes
Power Supply
Materials
Safety Devices
Accessories
Item
Gas
Consumption
Maximum Hot Water Capacity
Capacity Range
Temperature Settings
Default Temperature Options
• Specifications may be changed without prior notice.
• The capacity may differ slightly, depending on the water
Specifications
Installation
Air Supply/Exhaust
Water Inlet
Hot Water Outlet
Gas Inlet
Supply
Consumption
Casing
Flue Collar
Heat Exchanger
Performance
NG
LP
25°C (45°F) Rise
pressure, water supply, piping conditions, and water temperature.
NC250-SV-ASME
Indoor/Outdoor, Wall Mounted
Power Vented
2 L/min. (0.5 GPM)
619mm (24.4") x 468mm (18.4") x 240mm (9.4")
1.0L (0.3 Gallon)
120 VAC (60Hz)
NG : 115W LP : 115W
Freeze Prevention 250W
Stainless Steel
Stainless Steel
Copper Sheeting, Copper Tubing
Flame Rod, Thermal Fuse, Pressure Relief Valve,
Lightning Protection Device (ZNR),
Overheat Prevention Device, Freezing Prevention Device,
Fan Rotation Detector
Remote Controller, Remote Controller Cord,
Anchoring Screws
Maximum Performance
250,000 btuh
250,000 btuh
35.2 L/min. (9.3 Gal./min.)
2-42 L/min. (0.5-11.1 Gal./min.)
37-48°C (99-118°F) (In 1°C (5°F) intervals),
50-80°C (122-176°F) (In 5°C (10°F) intervals),
83°C (181°F) (20 Options)
50, 55, 60, 83°C (122,131,140,181°F)
(Original is 50°C (122°F))
Specification
NC250-DV-ASME
Indoor, Wall Mounted
Direct Vent (Sealed Combustion)
Direct Ignition
15-150 psi
62 lbs.
3/4"
3/4"
3/4"
NG : 115W
LP : 120W
Freeze Prevention 250W
Minimum Performance
11,000 btuh
11,000 btuh
29