Before to use the equipment, please verify the counterbalance of the lid. In case of rapid
−
descent of it (the didn't remain in open position) call immediately the assistance service
and do not use the machine.
Be very careful moving the lid, to avoid hands crushing due to suddenly falling of the lid,
−
use thick leather gloves.
Before cooking with the appliance for the first time wash the interior of the cooking vat thoroughly.
−
Warning! :
Fill the cooking vat up to a maximum of 40 mm under the overflow border, according
to the maximum level mark, including the food to be cooked.
Warning! :
The water level in the jacket must be checked each time before lighting.
Warning! :
It is advisable to use softened water to fill the jacket!
Open the level tap on the front of the appliance.
−
Unscrew the filling cap on the safety valve unit. The latter is on the right of the appliance surface (see
−
figure "Size of appliance and position of connections ").
Fill with softened water (the capacity of the jacket is stated in the paragraph "Technical data").
−
When water flows out of the level tap, close it and screw back on the safety unit cap.
−
Warning! :
The water level in the jacket must be checked each time before lighting.
Warning! :
It is advisable to use softened water to fill the jacket!
Open the level tap on the front of the appliance.
−
Unscrew the filling cap on the safety valve unit. The latter is on the right of the
−
appliance surface (see figure "Size of appliance and position of connections ").
Reposition the tap (an external hole is available) on the external pin of the relief
−
valve.
This operation is required to prevent water bubbles from forming in the jacket
−
during water loading. Water bubbles would not make it possible to reach a correct
water level in the jacket.
Fill with softened water (the capacity of the jacket is stated in the paragraph "Technical data").
−
When water flows out of the level tap, close it and screw back on the safety unit cap.
−
3.2.2. USE OF THE PRESSURE KETTLE LID (MODELS PM...... A)
Before switching on the appliance, close the lid firmly and tighten the 4 clamps.
−
The interior of the kettle can reach a maximum pressure of 0.05 bar.
–
When this pressure is exceeded, the pressure relief valve on the lid will start operating. On request, the
−
appliance is also available with a pressure gauge to display the pressure inside the kettle.
Warning! :
After cooking and before opening the lid, all the pressure inside the kettle must be
released by lifting the relief valve (see also figure "Relief valve".
Instruction manual for installation, maintenance and use
Gas Kettles PM.G...A
3.2. INSTRUCTIONS FOR USE
3.2.1. FILLING THE JACKET – MOD. 100-150LT.
MOD. 200/300/500 LT. – 170/270/370LT.
- GB -
16 di 28